Publications

Detailed Information

Two- versus three-dimensional colon evaluation with recently developed virtual dissection software for CT colonography

DC Field Value Language
dc.contributor.authorKim, Se Hyung-
dc.contributor.authorLee, Jeong Min-
dc.contributor.authorEun, Hyo Won-
dc.contributor.authorLee, Min Woo-
dc.contributor.authorHan, Joon Koo-
dc.contributor.authorLee, Jae Young-
dc.contributor.authorChoi, Byung Ihn-
dc.date.accessioned2009-10-14T07:08:25Z-
dc.date.available2009-10-14T07:08:25Z-
dc.date.issued2007-08-22-
dc.identifier.citationRadiology 2007;244:852-864en
dc.identifier.issn0033-8419 (Print)-
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=17709833-
dc.identifier.urihttps://hdl.handle.net/10371/10442-
dc.description.abstractThis retrospective study was institutional review board approved; the requirement for informed patient consent was waived. The purpose of this study was to retrospectively compare a two-dimensional (2D) data interpretation technique with a three-dimensional (3D) colon dissection technique in terms of interpretation time and sensitivity for colonic polyp detection, with colonoscopy as the reference standard. Ninety-six patients (56 men, 40 women; mean age, 54.8 years) underwent colonoscopy and multidetector computed tomographic (CT) colonography on the same day. Two radiologists independently analyzed the data on a per-polyp and per-patient basis. The sensitivity of both approaches was compared by using the McNemar test. The time required to interpret CT colonographic data with each technique was also assessed. Compared with the conventional 2D colonic polyp detection method, primary 3D interpretation with use of virtual dissection software for CT colonography revealed comparable per-polyp (77% and 69% for two readers) and per-patient (77% and 73% for two readers) sensitivities and comparable per-patient specificity (99% and 89% for two readers) for the detection of polyps 6 mm in diameter or larger and involved a shorter interpretation time.en
dc.language.isoenen
dc.publisherRadiological Society of North Americaen
dc.subjectAdulten
dc.subjectAgeden
dc.subjectColonic Polyps/*radiographyen
dc.subjectColonoscopyen
dc.subjectFemaleen
dc.subjectHumansen
dc.subjectImaging, Three-Dimensionalen
dc.subjectMaleen
dc.subjectMiddle Ageden
dc.subjectRadiographic Image Enhancementen
dc.subjectRadiographic Image Interpretation, Computer-Assisted/*methodsen
dc.subjectRetrospective Studiesen
dc.subjectStatistics, Nonparametricen
dc.subjectColonography, Computed Tomographic-
dc.subjectSoftware-
dc.titleTwo- versus three-dimensional colon evaluation with recently developed virtual dissection software for CT colonographyen
dc.typeArticleen
dc.contributor.AlternativeAuthor김세형-
dc.contributor.AlternativeAuthor이정민-
dc.contributor.AlternativeAuthor은효원-
dc.contributor.AlternativeAuthor이민우-
dc.contributor.AlternativeAuthor한준구-
dc.contributor.AlternativeAuthor이재영-
dc.contributor.AlternativeAuthor최병인-
dc.identifier.doi10.1148/radiol.2443060934-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share