Publications

Detailed Information

Rotational alignment of femoral component with different methods in total knee arthroplasty: a randomized, controlled trial

Cited 0 time in Web of Science Cited 0 time in Scopus
Authors

Lee, Joon Kyu; Lee, Sahnghoon; Chun, Sae Hyung; Kim, Ki Tae; Lee, Myung Chul

Issue Date
2017-05-25
Publisher
BioMed Central
Citation
BMC Musculoskeletal Disorders, 18(1):217
Keywords
Femoral component rotationGap techniqueMeasured resection techniqueTensor device
Abstract
Background
Femoral component rotation (FCR) is one of the most important factors in total knee arthroplasty. In this prospective study, we used three different techniques for FCR and analyzed their accuracy with postoperative axial computed tomography (CT) images. We also evaluated effect of FCR to clinical outcome.

Methods
One hundred sixty-five patients were randomly allocated into three groups. In the measured resection group, FCR was set by externally rotating the axis 3° off the posterior femoral condylar axis. In the tensor group, a gap-tensioning device set at 20 lbf was used. In the block group, spacer blocks of various thicknesses were used. The FCR angle (FCRa) was measured on postoperative axial CT as an angle between the clinical transepicondylar and posterior condylar axes of the femoral component. Outliers were defined as FCRas deviated more than 3° either internally or externally. Postoperative 2year clinical scores and knee range of motion were checked.

Results
The tensor group had significantly better positioning of the femoral component to the neutral position compared with the measured resection group and the block group (mean FCRa: internal rotation 1.79, 0.43 and 2.63°, respectively, p < 0.001). The outliers were also least frequent in the tensor group (35, 16 and 40%, respectively, p = 0.02). There were no significant differences in postoperative 2year clinical results among groups.

Conclusions
Gap technique with a 20-lbf tensor device was the most accurate and precise method for obtaining adequate FCR. Measured resection with 3° external rotation and gap technique with blocks could lead to internal rotation of the femoral component. Postoperative 2year clinical results were not significantly different among groups with different techniques for FCR.