Publications

Detailed Information

The safety and efficacy of transconjunctival sutureless 23-gauge vitrectomy

Cited 0 time in Web of Science Cited 37 time in Scopus
Authors

Kim, Moon Jung; Park, Kyu Hyung; Hwang, Jeong Min; Yu, Hyung Gon; Yu, Young Suk; Chung, Hum

Issue Date
2007-12-08
Publisher
Korean Journal of Ophthalmology
Citation
Korean J Ophthalmol. 2007 Dec;21(4):201-7.
Keywords
AdultAgedFemaleFollow-Up StudiesHumansIntraocular PressureMaleMiddle AgedRetinal Diseases/*surgeryRetrospective StudiesTreatment OutcomeVisual AcuityVitrectomy/*methodsVitreous Hemorrhage/*surgerySuture Techniques
Abstract
PURPOSE: To evaluate the efficacy and safety of vitreoretinal surgery using a 23-gauge transconjunctival sutureless vitrectomy (TSV) system for various vitreoretinal diseases. METHODS: A retrospective, consecutive, interventional case series was performed for 40 eyes of 40 patients. The patients underwent vitreoretinal procedures using the 23-gauge TSV system, including idiopathic epiretinal membrane (n=7), vitreous hemorrhage (n=11), diabetic macular edema (n=10), macular hole (n=5), vitreomacular traction syndrome (n=5), diabetic tractional retinal detachment (n=1), and rhegmatogenous retinal detachment (n=1). Best corrected visual acuity (BCVA), intraocular pressure (IOP), and intra- and post-operative complications were evaluated. RESULTS: Intraoperative suture placement was necessary in 3 eyes (7.5%). The median BCVA improved from 20/400 (LogMAR, 1.21+/-0.63) to 20/140 (LogMAR, 0.83+/-0.48) at 1 week (p=0.003), 20/100 (LogMAR, 0.85+/-0.65) at 1 month (p=0.002), 20/100 (LogMAR, 0.73+/-0.6) at 3 months (p=0.001). In 1 eye, IOP was 5 mmHg at 2 hours and 4 mmHg at 5 hours, but none of the eyes showed hypotony after 1 postoperative day. No serous postoperative complications were observed during a mean follow-up of 8.4+/-3.4 months (range 3-13 months) CONCLUSIONS: The 23-gauge TSV system shows promise as an effective and safe technique for a variety of vitreoretinal procedures. It appears to be a less traumatic, more convenient alternative to 20-gauge vitrectomy in some indications.
ISSN
1011-8942 (Print)
Language
English
URI
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=18063883

https://hdl.handle.net/10371/16816
DOI
https://doi.org/10.3341/kjo.2007.21.4.201
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share