Publications

Detailed Information

Consideration of serum glucose levels during malignant mediastinal lymph node detection in non-small-cell lung cancer by FDG-PET

DC Field Value Language
dc.contributor.authorLee, Won Woo-
dc.contributor.authorChung, Jin-Haeng-
dc.contributor.authorJang, Sung-June-
dc.contributor.authorEo, Jae Seon-
dc.contributor.authorPark, So Yeon-
dc.contributor.authorSung, Sook Whan-
dc.contributor.authorSo, Young-
dc.contributor.authorChung, June-Key-
dc.contributor.authorLee, Myung Chul-
dc.contributor.authorKim, Sang Eun-
dc.date.accessioned2010-01-07T02:04:46Z-
dc.date.available2010-01-07T02:04:46Z-
dc.date.issued2006-10-14-
dc.identifier.citationJ Surg Oncol. 2006 Dec 1;94(7):607-13.en
dc.identifier.issn0022-4790 (Print)-
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=17039492-
dc.identifier.urihttps://hdl.handle.net/10371/27822-
dc.description.abstractBACKGROUND AND OBJECTIVE: Glucose and FDG compete for uptake by cancers. Here, we undertook to improve diagnostic accuracy of FDG-PET for determining mediastinal lymph node (LN) status in NSCLC by considering serum glucose level. METHODS: NSCLC patients (n = 70) who underwent curative lung resection and mediastinal LN dissection within 1 month of FDG-PET were enrolled. MaxSUV was calculated using lean body weight and used to determine a new parameter (maxSUV x serum glucose level; maxSUV-GL). Histopathologic LN results were compared with maxSUV and maxSUV-GL values. RESULTS: Of 71 LN stations whose FDG uptake could be measured, 21 were malignant and 50 benign. MaxSUV of LN had AUC of 0.729 (95% CI: 0.610-0.827) by ROC analysis with sensitivity of 47.6% (10/21), specificity of 94.0% (47/50), and a cutoff value of 3.3. Using maxSUV-GL the corresponding values were; AUC 0.825 (95% CI: 0.716-0.905) and sensitivity 76.2% (16/21), with a cutoff value of 290.4, which represented a significant improvement (P < 0.01) without compromising specificity 88.0% (44/50) (P > 0.05). The exclusion of neo-adjuvant chemotherapeutic and diabetic patients resulted in a similar improvement in diagnostic accuracy. CONCLUSION: By considering serum glucose level during FDG-PET using the new parameter maxSUV-GL, sensitivity for malignant mediastinal LN detection is improved.en
dc.language.isoenen
dc.publisherJohn Wiley & Sonsen
dc.subjectBlood Glucose/*analysisen
dc.subjectCarcinoma, Non-Small-Cell Lung/blood/*radionuclide imaging/secondaryen
dc.subjectDiabetes Complications/blooden
dc.subjectFluorodeoxyglucose F18/*diagnostic use/pharmacokineticsen
dc.subjectHumansen
dc.subjectLung Neoplasms/blood/pathology/*radionuclide imagingen
dc.subjectLymph Nodes/pathology/*radionuclide imagingen
dc.subjectLymphatic Metastasisen
dc.subjectMediastinumen
dc.subjectROC Curveen
dc.subjectRadiopharmaceuticals/*diagnostic useen
dc.subjectSensitivity and Specificityen
dc.titleConsideration of serum glucose levels during malignant mediastinal lymph node detection in non-small-cell lung cancer by FDG-PETen
dc.typeArticleen
dc.contributor.AlternativeAuthor이원우-
dc.contributor.AlternativeAuthor정진행-
dc.contributor.AlternativeAuthor장성준-
dc.contributor.AlternativeAuthor어재선-
dc.contributor.AlternativeAuthor박소연-
dc.contributor.AlternativeAuthor성숙환-
dc.contributor.AlternativeAuthor소영-
dc.contributor.AlternativeAuthor정준기-
dc.contributor.AlternativeAuthor이명철-
dc.contributor.AlternativeAuthor김상은-
dc.identifier.doi10.1002/jso.20624-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share