Publications

Detailed Information

삼차원 유한 요소법에 의한 가철성 국소의치 클래스프의 응력 분석 : STRESS ANALYSIS ON THE DIFFERENT CLASPS OF THE REMOVABLE PARTIAL DENTURE BY THREE-DIMENSIONAL FINITE ELEMENT METHOD

DC Field Value Language
dc.contributor.author박홍렬-
dc.contributor.author김성균-
dc.contributor.author곽재영-
dc.contributor.author허성주-
dc.date.accessioned2010-02-01T06:10:09Z-
dc.date.available2010-02-01T06:10:09Z-
dc.date.issued2005-
dc.identifier.citation2005;43:2en
dc.identifier.issn0301-2875-
dc.identifier.urihttps://hdl.handle.net/10371/47398-
dc.description.abstractStatement of problem. In the partially edentulous patients, removable partial dentures have been working as a important treatment modality. Clasps, a kind of direct retainers, received some amount of stresses during the insertion and removal of partial denture on the abutment tooth. Purpose. The study is to investigate stresses of the different clasps. Material and methods. In order to investigate the degree of stresses, maxillary partial edentulism (Kennedy Class II modification I) was assumed and removable partial dentures were designed on it with three kinds of metallic materials; cobalt-chromium alloy, type IV gold alloy and commercially pure (c.p.) titanium. Aker's clasp was applied on the left second molar. RPA (mesial rest-proximal plate-Aker's) clasp was on the left first premolar and wrought wire clasp was on the right first premolar. Three dimensional, non-linear, dynamic finite element analysis method was run to solve this process. Results. 1. Cobalt-chromium alloy had the highest von Mises stress value and c.p. titanium had the lowest one irrespective of the types of clasps. 2. In the Aker's clasps, stress on the retentive tips was shown shortly after the appearance of stresses of the middle and minor connector areas. These time lag was much shorter in the RPA clasps than in the Aker's clasp. 3. In general. retentive tips of wrought wire clasps had much less amount of stress than other clasps. Conclusion. The amount of stress was the highest in the RPA clasp and the lowest in the wrought wire clasp, in general.en
dc.language.isokoen
dc.publisher대한치과보철학회en
dc.subjectClaspen
dc.subjectRemovable partial dentureen
dc.subjectStressen
dc.subjectFinite element analysisen
dc.title삼차원 유한 요소법에 의한 가철성 국소의치 클래스프의 응력 분석en
dc.title.alternativeSTRESS ANALYSIS ON THE DIFFERENT CLASPS OF THE REMOVABLE PARTIAL DENTURE BY THREE-DIMENSIONAL FINITE ELEMENT METHODen
dc.typeArticleen
dc.author.alternative장익태-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share