- This paper describes the development of integrated head and eye tracker system. Vision based head tracker is
performed and it has 7mm error in 300mm translation. The epi-polar method and point matching are used for determining a
position of head and rotational degree. High brightness LEDs are installed on helmet and the installed pattern is very important
to match the points of stereo system. Eye tracker also uses LED for constant illumination. A Position of gazed object(3m
distance) is determined by pupil tracking and eye tracker has 1~5 pixel error. Integration of result data of each tracking system
is important. RS-232C communication is applied to integrated system and triggering signal is used for synchronization.