Automatic ballistocardiogram (BCG) beat detection using a template matching approach

DC Field Value Language
dc.contributor.authorShin, J H-
dc.contributor.authorChoi, B H-
dc.contributor.authorLim, Y G-
dc.contributor.authorJeong, D U-
dc.contributor.authorPark, K S-
dc.date.accessioned2010-06-28-
dc.date.available2010-06-28-
dc.date.issued2009-01-24-
dc.identifier.citationConf Proc IEEE Eng Med Biol Soc. 2008;1144-1146en
dc.identifier.issn1557-170X (Print)-
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=19162866-
dc.identifier.urihttp://ieeexplore.ieee.org/stampPDF/getPDF.jsp?tp=&arnumber=04649363&isnumber=4649055-
dc.identifier.urihttps://hdl.handle.net/10371/67883-
dc.description.abstractThis paper suggests a beat detection method for ballistocardiogram (BCG) from an unconstrained cardiac signal monitoring devices. A fiducial peak point of BCG is an I-J-K complex which corresponds with ventricle contraction and Electrocardiogram (ECG) QRS complex. The goal of the method is extraction of J peak without ECG synchronization. The detection method is based on a "template matching" rule evaluated using a correlation function in a local moving-window procedure. The total beat detection algorithm operates in two stages, template definition stage and beat detection stage with defined template in previous stage. In the first stage, the BCG template is constructed by the expert with an empirical analysis of BCG signal and measurement device. In the second stage, the correlation function calculates an accuracy of template with BCG signal using a local moving-window. The data analysis has been performed on the subjects tested at Seoul National University Hospital Sleep Medicine Center and presents 95.16% of sensitivity and 94.76% of positive predictivity value for the J peak detection.en
dc.language.isoenen
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)en
dc.subjectBallistocardiography/*methodsen
dc.subjectDiagnosis, Computer-Assisted/*methodsen
dc.subjectHeart Rate/*physiologyen
dc.subjectPattern Recognition, Automated/*methodsen
dc.subjectReproducibility of Resultsen
dc.subjectSensitivity and Specificityen
dc.subjectAlgorithms-
dc.subjectArtificial Intelligence-
dc.titleAutomatic ballistocardiogram (BCG) beat detection using a template matching approachen
dc.typeArticleen
dc.identifier.doi10.1109/IEMBS.2008.4649363-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share