Publications
Detailed Information
The effect of consistency, specimen geometry and adhesion on the axial polymerization shrinkage measurement of light cured composites
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Son, Ho-Hyun | - |
dc.contributor.author | Lee, In-Bog | - |
dc.contributor.author | Cho, Byeong-Hoon | - |
dc.contributor.author | Um, Chung-Moon | - |
dc.contributor.author | Lim, Bum-Soon | - |
dc.date.accessioned | 2010-09-03T04:48:19Z | - |
dc.date.available | 2010-09-03T04:48:19Z | - |
dc.date.issued | 2006-11 | - |
dc.identifier.citation | DENTAL MATERIALS 2006;22:1071-1079 | en |
dc.identifier.issn | 0109-5641 | - |
dc.identifier.uri | https://hdl.handle.net/10371/69647 | - |
dc.description.abstract | Objectives
This study investigated the effect of the consistency, specimen geometry and adhesion on the measurements of axial polymerization shrinkage of light cured composite resins using an axial shrinkage-measuring device. Methods Four commercially available composites were examined: an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow. The axial polymerization shrinkage of the composites was determined using a bonded disc method and non-bonded free shrinkage method at varying C-factors by altering the specimen geometry. These measured axial shrinkages were compared with the free volumetric shrinkages. The consistency of the composites was also compared using a squeeze test. Results Using the non-bonded method, the axial shrinkage was approximately one third of the true volumetric shrinkage as a result of isotropic contraction. However, in the bonded disc method, the axial shrinkage increased up to the volumetric shrinkage by anisotropic contraction as the bonded surface increased. The axial shrinkage increased with the increasing C-factor. It approached the true volumetric shrinkage and reached a plateau at near a C-factor of 5–6. However, in flowable composites, a lower level of axial shrinkage was measured by the compensational radial flow. Significance When estimating the volumetric shrinkage from the axial shrinkage measured using the bonded disc method, the C-factor of the specimen should be higher than 5 and the consistency of the composite is also an important factor that needs to be considered. | en |
dc.description.sponsorship | This study was supported in part by a grant (no. 03-PJ1-PG1-
CH09-0001) from the Ministry of Health andWelfare, Republic of Korea. | en |
dc.language.iso | en | en |
dc.publisher | Elsevier | en |
dc.subject | Anisotropy | en |
dc.subject | Polymerization shrinkage | en |
dc.subject | Bonded disc method | en |
dc.subject | Flow | en |
dc.subject | Consistency | en |
dc.subject | C-factor | en |
dc.subject | Light cured composites | en |
dc.title | The effect of consistency, specimen geometry and adhesion on the axial polymerization shrinkage measurement of light cured composites | en |
dc.type | Article | en |
dc.contributor.AlternativeAuthor | 손호현 | - |
dc.contributor.AlternativeAuthor | 이인복 | - |
dc.contributor.AlternativeAuthor | 조병훈 | - |
dc.contributor.AlternativeAuthor | 엄정문 | - |
dc.contributor.AlternativeAuthor | 임범순 | - |
dc.identifier.doi | 10.1016/j.dental.2005.08.012 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.