Publications
Detailed Information
Quantitative analysis of errors in alveolar crest level caused by discrepant projection geometry in digital subtraction radiography: an in vivo study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yi, Won-Jin | - |
dc.contributor.author | Huh, Kyung-Hoe | - |
dc.contributor.author | Lee, Sam-Sun | - |
dc.contributor.author | Jeon, In-Seong | - |
dc.contributor.author | Heo, Min-Suk | - |
dc.contributor.author | Choi, Soon-Chul | - |
dc.date.accessioned | 2010-09-06 | - |
dc.date.available | 2010-09-06 | - |
dc.date.issued | 2005-12 | - |
dc.identifier.citation | Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2005;100:750-755 | en |
dc.identifier.issn | 1079-2104 | - |
dc.identifier.uri | https://hdl.handle.net/10371/69708 | - |
dc.description.abstract | Objective
This study compared the difference between 3 intraoral radiographic techniques on digital subtraction radiography (DSR) in vivo that are commonly used in a clinical setting. Study design We evaluated and statistically analyzed the errors in the DSR image in 6 regions with 3 radiographic techniques: paralleling technique with a bite block attached to XCP, paralleling technique using XCP, and bisecting-angle technique. Results The amount of error using the bisecting-angle technique was too large for DSR, compared to that of the paralleling technique with a bite block attached to XCP. In the mandibular anterior region, the paralleling technique using XCP was not different from paralleling technique with a bite block attached to XCP. The lowest degree of error was present in the anterior region whereas the highest was present in the molar region. Conclusion Bisecting-angle technique should be avoided, and paralleling technique using XCP can be used in the mandibular anterior region for DSR. | en |
dc.description.sponsorship | This study was supported by a grant of the Korea Health 21 R&D
Project, Ministry of Health & Welfare, Republic of Korea (01-PJ5- PG1-01CH12-0002). | en |
dc.language.iso | en | en |
dc.publisher | Elsevier | en |
dc.title | Quantitative analysis of errors in alveolar crest level caused by discrepant projection geometry in digital subtraction radiography: an in vivo study | en |
dc.type | Article | en |
dc.contributor.AlternativeAuthor | 이원진 | - |
dc.contributor.AlternativeAuthor | 허경호 | - |
dc.contributor.AlternativeAuthor | 이삼순 | - |
dc.contributor.AlternativeAuthor | 전인성 | - |
dc.contributor.AlternativeAuthor | 허민숙 | - |
dc.contributor.AlternativeAuthor | 최순철 | - |
dc.identifier.doi | 10.1016/j.tripleo.2005.03.005 | - |