Results of immediate loading for implant restoration in partially edentulous patients: a 6-month preliminary prospective study using SinusQuickTM EB system

Cited 0 time in Web of Science Cited 5 time in Scopus
Authors

Yeo, In-Sung; Kim, Jong-Hwa; Kim, Young-Kyun; Yi, Yang-Jin; Yun, Pil-Young; Lee, Hyo-Jung; Kim, Myung-Jin

Issue Date
2009-11
Publisher
The Korean Academy of Prosthodontics
Citation
Journal of Advanced Prosthodontics 2009;1:136-139
Keywords
Immediate loadingPartially edentulousDental implantProspective clinical studyMarginal bone loss
Abstract
STATEMENT OF PROBLEM. Many dental clinicians are concerned about immediate loading of inserted implants. However, there have been
few clinical studies surveying the success rates of immediate loading, based on Korean implant systems. PURPOSE. The aim of this study was to evaluate the outcome of immediate functional loading of the implant (SinusQuickTM EB, Neobiotech Co., Seoul, Korea) in partially edentulous
maxilla or mandible. MATERIAL AND METHODS. Total 15 implants were placed. Within 2 weeks after implant insertion, provisional
implant-supported fixed partial dentures were delivered to the patients. Quantitatively, marginal bone loss was measured at the time of immediate
loading, after 3-months of continued loading and at the last follow-up. The mean follow-up period was 4.8 months. RESULTS. Mean marginal bone loss from implant surgery to early loading, 3-months follow-up and last follow-up was 0.03 ± 0.07 mm, 0.16 ± 0.17 mm and 0.29 ± 0.19 mm. No implant failed up to 6 months after insertion, resulting in a 100% survival rate. CONCLUSION. Immediate loading exhibited high success rate in partial edentulism for up to 6 months. Well-controlled long term clinical studies with large sample size are necessary to confirm this finding.
ISSN
2005-7806
Language
English
URI
https://hdl.handle.net/10371/72049
DOI
https://doi.org/10.4047/jap.2009.1.3.136
Files in This Item:
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share