Publications
Detailed Information
Accuracy of Platelet Counting by Automated Hematologic Analyzers in Acute Leukemia and Disseminated lntravascular Coagulation Potential Effects of Platelet Activation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Seon Young | - |
dc.contributor.author | Kim, Ji-Eun | - |
dc.contributor.author | Han, Kyou-Sup | - |
dc.contributor.author | Kim, Hyun Kyung | - |
dc.contributor.author | Toh, Cheng Hock | - |
dc.date.accessioned | 2012-05-22T09:01:13Z | - |
dc.date.available | 2012-05-22T09:01:13Z | - |
dc.date.issued | 2010-10 | - |
dc.identifier.citation | AMERICAN JOURNAL OF CLINICAL PATHOLOGY; Vol.134 4; 634-647 | ko_KR |
dc.identifier.issn | 0002-9173 | - |
dc.identifier.uri | https://hdl.handle.net/10371/76261 | - |
dc.description.abstract | Platelet counting in patients with acute leukemia or disseminated intravascular coagulation (DIC) may have a risk for erroneous counts owing to the presence of nonplatelet particles or platelet activation. We evaluated automated platelet counting methods using the Abbott Cell-Dyn Sapphire (Abbott Diagnostics, Santa Clara, CA), Sysmex XE-2100 (Sysmex, Kobe, Japan), AD VIA 2120 (Siemens Diagnostics, Tarrytown, NY), and Beckman Coulter LH 750 (Beckman Coulter, Miami, FL) compared with the international reference method (IRM). Automated platelet counting methods were inaccurate compared with the IRM, without evidence of interfering nonplatelet particles. It is interesting that platelet activation markers were associated with DIC severity and erroneous platelet counting, suggesting that platelet activation is a potential source of inaccuracy. Furthermore, the artifactual in vitro platelet activation induced a high degree of intermethod variation in platelet counts. The inaccuracy of automated platelet counts increased the risk for misdiagnosis of DIC. More attention needs to be given to the accuracy of platelet counts, especially in clinical conditions with florid platelet activation. | ko_KR |
dc.language.iso | en | ko_KR |
dc.publisher | AMER SOC CLINICAL PATHOLOGY | ko_KR |
dc.subject | Platelet count | ko_KR |
dc.subject | Acute leukemia | ko_KR |
dc.subject | Disseminated intravascular coagulation | ko_KR |
dc.subject | Platelet activation | ko_KR |
dc.title | Accuracy of Platelet Counting by Automated Hematologic Analyzers in Acute Leukemia and Disseminated lntravascular Coagulation Potential Effects of Platelet Activation | ko_KR |
dc.type | Article | ko_KR |
dc.contributor.AlternativeAuthor | 김선영 | - |
dc.contributor.AlternativeAuthor | 김현경 | - |
dc.contributor.AlternativeAuthor | 한규섭 | - |
dc.contributor.AlternativeAuthor | 김지은 | - |
dc.identifier.doi | 10.1309/AJCP88JYLRCSRXPP | - |
dc.citation.journaltitle | AMERICAN JOURNAL OF CLINICAL PATHOLOGY | - |
dc.description.citedreference | Hong KH, 2009, INT J LAB HEMATOL, V31, P298, DOI 10.1111/j.1751-553X.2008.01032.x | - |
dc.description.citedreference | Apelseth TO, 2007, TRANSFUS APHER SCI, V37, P261, DOI 10.1016/j.transci.2007.02.006 | - |
dc.description.citedreference | Zandecki M, 2007, INT J LAB HEMATOL, V29, P4, DOI 10.1111/j.1365-2257.2006.00870.x | - |
dc.description.citedreference | Branda JA, 2006, AM J CLIN PATHOL, V126, P248, DOI 10.1039/1G5HB7PAK8V0KAR7 | - |
dc.description.citedreference | Segal HC, 2005, BRIT J HAEMATOL, V128, P520, DOI 10.1111/j.1365-2141.2004.05352.x | - |
dc.description.citedreference | Hervig T, 2004, VOX SANG, V87, P196 | - |
dc.description.citedreference | Bland JM, 2003, ULTRASOUND OBST GYN, V22, P85, DOI 10.1002/uog.122 | - |
dc.description.citedreference | Kelsey P, 2003, BRIT J HAEMATOL, V122, P10 | - |
dc.description.citedreference | Norris S, 2003, BRIT J HAEMATOL, V121, P605 | - |
dc.description.citedreference | 2003, FED REG, V68, P3639 | - |
dc.description.citedreference | VANDERMEE, 2003, J CLIN PATHOL, V56, P772 | - |
dc.description.citedreference | Sandhaus LM, 2002, AM J CLIN PATHOL, V118, P235 | - |
dc.description.citedreference | Hickerson DHM, 2002, HEMATOL ONCOL CLIN N, V16, P421 | - |
dc.description.citedreference | Taylor FB, 2001, THROMB HAEMOSTASIS, V86, P1327 | - |
dc.description.citedreference | Arroyo JL, 2001, TRANSFUSION, V41, P1212 | - |
dc.description.citedreference | Johannessen B, 2001, TRANSFUS APHER SCI, V25, P93 | - |
dc.description.citedreference | Chapman DH, 2001, AM J CLIN PATHOL, V115, P894 | - |
dc.description.citedreference | Klee G, 2001, AM J CLIN PATHOL, V115, P460 | - |
dc.description.citedreference | Harrison P, 2001, AM J CLIN PATHOL, V115, P448 | - |
dc.description.citedreference | Kunz D, 2001, BRIT J HAEMATOL, V112, P584 | - |
dc.description.citedreference | KEENEY M, 2001, LAB HEMATOL, V7, P204 | - |
dc.description.citedreference | Briggs C, 2000, CLIN LAB HAEMATOL, V22, P345 | - |
dc.description.citedreference | Harrison P, 2000, BRIT J HAEMATOL, V108, P228 | - |
dc.description.citedreference | Li SY, 1999, ARCH PATHOL LAB MED, V123, P1111 | - |
dc.description.citedreference | Macey MG, 1999, CYTOMETRY, V38, P250 | - |
dc.description.citedreference | Springer W, 1998, BLOOD, V92, P2183 | - |
dc.description.citedreference | HAMMERSTROM J, 1992, CLIN LAB HAEMATOL, V14, P239 | - |
dc.description.citedreference | HIROKAWA M, 1990, ACTA PATHOL JAPON, V40, P908 | - |
dc.description.citedreference | KRAUSS JS, 1989, MODERN PATHOL, V2, P301 | - |
dc.description.citedreference | BALLARD HS, 1981, ARCH INTERN MED, V141, P942 | - |
dc.description.citedreference | MALCOLM ID, 1978, NEW ENGL J MED, V298, P1260 | - |
dc.description.tc | 2 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.