dc.identifier.citationAMERICAN JOURNAL OF CLINICAL PATHOLOGY; Vol.134 4; 634-647ko_KR
dc.identifier.issn0002-9173-
dc.identifier.urihttps://hdl.handle.net/10371/76261-
dc.description.abstractPlatelet counting in patients with acute leukemia or disseminated intravascular coagulation (DIC) may have a risk for erroneous counts owing to the presence of nonplatelet particles or platelet activation. We evaluated automated platelet counting methods using the Abbott Cell-Dyn Sapphire (Abbott Diagnostics, Santa Clara, CA), Sysmex XE-2100 (Sysmex, Kobe, Japan), AD VIA 2120 (Siemens Diagnostics, Tarrytown, NY), and Beckman Coulter LH 750 (Beckman Coulter, Miami, FL) compared with the international reference method (IRM). Automated platelet counting methods were inaccurate compared with the IRM, without evidence of interfering nonplatelet particles. It is interesting that platelet activation markers were associated with DIC severity and erroneous platelet counting, suggesting that platelet activation is a potential source of inaccuracy. Furthermore, the artifactual in vitro platelet activation induced a high degree of intermethod variation in platelet counts. The inaccuracy of automated platelet counts increased the risk for misdiagnosis of DIC. More attention needs to be given to the accuracy of platelet counts, especially in clinical conditions with florid platelet activation.ko_KR
dc.language.isoenko_KR
dc.publisherAMER SOC CLINICAL PATHOLOGYko_KR
dc.subjectPlatelet countko_KR
dc.subjectAcute leukemiako_KR
dc.subjectDisseminated intravascular coagulationko_KR
dc.subjectPlatelet activationko_KR
dc.titleAccuracy of Platelet Counting by Automated Hematologic Analyzers in Acute Leukemia and Disseminated lntravascular Coagulation Potential Effects of Platelet Activationko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor김선영-
dc.contributor.AlternativeAuthor김현경-
dc.contributor.AlternativeAuthor한규섭-
dc.contributor.AlternativeAuthor김지은-
dc.identifier.doi10.1309/AJCP88JYLRCSRXPP-
dc.citation.journaltitleAMERICAN JOURNAL OF CLINICAL PATHOLOGY-
dc.description.citedreferenceHong KH, 2009, INT J LAB HEMATOL, V31, P298, DOI 10.1111/j.1751-553X.2008.01032.x-
dc.description.citedreferenceApelseth TO, 2007, TRANSFUS APHER SCI, V37, P261, DOI 10.1016/j.transci.2007.02.006-
dc.description.citedreferenceZandecki M, 2007, INT J LAB HEMATOL, V29, P4, DOI 10.1111/j.1365-2257.2006.00870.x-
dc.description.citedreferenceBranda JA, 2006, AM J CLIN PATHOL, V126, P248, DOI 10.1039/1G5HB7PAK8V0KAR7-
dc.description.citedreferenceSegal HC, 2005, BRIT J HAEMATOL, V128, P520, DOI 10.1111/j.1365-2141.2004.05352.x-
dc.description.citedreferenceHervig T, 2004, VOX SANG, V87, P196-
dc.description.citedreferenceBland JM, 2003, ULTRASOUND OBST GYN, V22, P85, DOI 10.1002/uog.122-
dc.description.citedreferenceKelsey P, 2003, BRIT J HAEMATOL, V122, P10-
dc.description.citedreferenceNorris S, 2003, BRIT J HAEMATOL, V121, P605-
dc.description.citedreference2003, FED REG, V68, P3639-
dc.description.citedreferenceVANDERMEE, 2003, J CLIN PATHOL, V56, P772-
dc.description.citedreferenceSandhaus LM, 2002, AM J CLIN PATHOL, V118, P235-
dc.description.citedreferenceHickerson DHM, 2002, HEMATOL ONCOL CLIN N, V16, P421-
dc.description.citedreferenceTaylor FB, 2001, THROMB HAEMOSTASIS, V86, P1327-
dc.description.citedreferenceArroyo JL, 2001, TRANSFUSION, V41, P1212-
dc.description.citedreferenceJohannessen B, 2001, TRANSFUS APHER SCI, V25, P93-
dc.description.citedreferenceChapman DH, 2001, AM J CLIN PATHOL, V115, P894-
dc.description.citedreferenceKlee G, 2001, AM J CLIN PATHOL, V115, P460-
dc.description.citedreferenceHarrison P, 2001, AM J CLIN PATHOL, V115, P448-
dc.description.citedreferenceKunz D, 2001, BRIT J HAEMATOL, V112, P584-
dc.description.citedreferenceKEENEY M, 2001, LAB HEMATOL, V7, P204-
dc.description.citedreferenceBriggs C, 2000, CLIN LAB HAEMATOL, V22, P345-
dc.description.citedreferenceHarrison P, 2000, BRIT J HAEMATOL, V108, P228-
dc.description.citedreferenceLi SY, 1999, ARCH PATHOL LAB MED, V123, P1111-
dc.description.citedreferenceMacey MG, 1999, CYTOMETRY, V38, P250-
dc.description.citedreferenceSpringer W, 1998, BLOOD, V92, P2183-
dc.description.citedreferenceHAMMERSTROM J, 1992, CLIN LAB HAEMATOL, V14, P239-
dc.description.citedreferenceHIROKAWA M, 1990, ACTA PATHOL JAPON, V40, P908-
dc.description.citedreferenceKRAUSS JS, 1989, MODERN PATHOL, V2, P301-
dc.description.citedreferenceBALLARD HS, 1981, ARCH INTERN MED, V141, P942-
dc.description.citedreferenceMALCOLM ID, 1978, NEW ENGL J MED, V298, P1260-
dc.description.tc2-