Publications

Detailed Information

Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement

DC Field Value Language
dc.contributor.authorLee, Seung Min-
dc.contributor.authorSim, Kyo Sik-
dc.contributor.authorKim, Ko Keun-
dc.contributor.authorLim, Yong Gyu-
dc.contributor.authorPark, Kwang Suk-
dc.date.accessioned2012-06-28T07:34:04Z-
dc.date.available2012-06-28T07:34:04Z-
dc.date.issued2010-05-
dc.identifier.citationMEDICAL & BIOLOGICAL ENGINEERING & COMPUTING; Vol.48 5; 447-457ko_KR
dc.identifier.issn0140-0118-
dc.identifier.urihttps://hdl.handle.net/10371/77799-
dc.description.abstractCapacitive electrocardiogram (ECG) measurement over clothing requires large electrodes that can remain in contact with curved body surfaces to increase the signal-to-noise ratio (SNR). In this article, we propose a new, thin, and flexible active electrode for use as a capacitive ECG measurement electrode. This electrode contains a shielding plate over its surface and it is extremely thin and can bend freely to cover larger body surfaces of the curve-shaped human torso. We evaluated the characteristics of flexible active electrodes under conditions of varying cloth thickness, electrode size, and contacting pressure. Electrodes of two sizes (45 and 12 cm(2)) were attached to a chest belt to measure the ECG from the human torso, and the results obtained for both the sizes were compared. Cloth thickness and electrode size showed a dominant effect on the SNR, whereas contacting pressure had almost no effect. The flexible active electrodes attached to chest belts wrapped closely and uniformly over the curved surface of the torso and SNR was increased with an increase in electrode size. Although the ECG signal became more distorted as the cloth thickness increased, the larger-sized flexible active electrode (45 cm(2)) showed less distortion than the smaller-sized one (12 cm(2)).ko_KR
dc.language.isoenko_KR
dc.publisherSPRINGER HEIDELBERGko_KR
dc.subjectActive electrodeko_KR
dc.subjectUnconstrained ECG measurementko_KR
dc.subjectCapacitive ECGko_KR
dc.subjectFlexible electrodeko_KR
dc.titleThin and flexible active electrodes with shield for capacitive electrocardiogram measurementko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor이승민-
dc.contributor.AlternativeAuthor심교식-
dc.contributor.AlternativeAuthor김고건-
dc.contributor.AlternativeAuthor임용규-
dc.contributor.AlternativeAuthor박광석-
dc.identifier.doi10.1007/s11517-010-0597-y-
dc.citation.journaltitleMEDICAL & BIOLOGICAL ENGINEERING & COMPUTING-
dc.description.citedreferenceRantanen V, 2010, MED BIOL ENG COMPUT, V48, P39, DOI 10.1007/s11517-009-0565-6-
dc.description.citedreferenceJi ZY, 2009, MED BIOL ENG COMPUT, V47, P1045, DOI 10.1007/s11517-009-0516-2-
dc.description.citedreferenceSzucs K, 2009, MED BIOL ENG COMPUT, V47, P487, DOI 10.1007/s11517-009-0485-5-
dc.description.citedreferenceRissanen SM, 2008, MED BIOL ENG COMPUT, V46, P849, DOI 10.1007/s11517-008-0369-0-
dc.description.citedreferenceUeno A, 2007, IEEE T BIO-MED ENG, V54, P759, DOI 10.1109/TBME.2006.889201-
dc.description.citedreferenceLim YG, 2007, IEEE T BIO-MED ENG, V54, P718, DOI 10.1109/TBME.2006.889194-
dc.description.citedreferenceLim YG, 2006, IEEE T BIO-MED ENG, V53, P956, DOI 10.1109/TBME.2006.872823-
dc.description.citedreferenceSEO JW, 2003, IEEE EMBS AS PAC C B-
dc.description.citedreferenceSEO W, 2003, IEEE EMBS AS PAC C B-
dc.description.citedreferenceANDREONI G, 2000, ANN INT C IEEE EMBS-
dc.description.citedreferenceGUYTON AC, 2000, TXB MED PHYSL, P107-
dc.description.citedreferenceTAMURA T, 1997, BIOMED INSTRUM TECHN, V31, P391-
dc.description.citedreferenceBAXTER LK, 1997, CAPACITIVE SENSORS D, P147-
dc.description.citedreferenceISHIJIMA M, 1993, IEEE T BIO-MED ENG, V40, P593, DOI 10.1109/10.237680-
dc.description.citedreferenceREITZ JR, 1993, FDN ELECTROMAGNETIC, P141-
dc.description.citedreferenceVANRIJN ACM, 1990, MED BIOL ENG COMPUT, V28, P389-
dc.description.citedreferenceWINTER BB, 1983, IEEE T BIO-MED ENG, V30, P58-
dc.description.citedreferenceNEUMAN MR, 1978, MED INSTRUMENTATION-
dc.description.citedreferenceLOPEZ A, 1969, IEEE T BIO-MED ENG, VBM16, P99-
dc.description.tc1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share