Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Seung Min | - |
dc.contributor.author | Sim, Kyo Sik | - |
dc.contributor.author | Kim, Ko Keun | - |
dc.contributor.author | Lim, Yong Gyu | - |
dc.contributor.author | Park, Kwang Suk | - |
dc.date.accessioned | 2012-06-28T07:34:04Z | - |
dc.date.available | 2012-06-28T07:34:04Z | - |
dc.date.issued | 2010-05 | - |
dc.identifier.citation | MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING; Vol.48 5; 447-457 | ko_KR |
dc.identifier.issn | 0140-0118 | - |
dc.identifier.uri | https://hdl.handle.net/10371/77799 | - |
dc.description.abstract | Capacitive electrocardiogram (ECG) measurement over clothing requires large electrodes that can remain in contact with curved body surfaces to increase the signal-to-noise ratio (SNR). In this article, we propose a new, thin, and flexible active electrode for use as a capacitive ECG measurement electrode. This electrode contains a shielding plate over its surface and it is extremely thin and can bend freely to cover larger body surfaces of the curve-shaped human torso. We evaluated the characteristics of flexible active electrodes under conditions of varying cloth thickness, electrode size, and contacting pressure. Electrodes of two sizes (45 and 12 cm(2)) were attached to a chest belt to measure the ECG from the human torso, and the results obtained for both the sizes were compared. Cloth thickness and electrode size showed a dominant effect on the SNR, whereas contacting pressure had almost no effect. The flexible active electrodes attached to chest belts wrapped closely and uniformly over the curved surface of the torso and SNR was increased with an increase in electrode size. Although the ECG signal became more distorted as the cloth thickness increased, the larger-sized flexible active electrode (45 cm(2)) showed less distortion than the smaller-sized one (12 cm(2)). | ko_KR |
dc.language.iso | en | ko_KR |
dc.publisher | SPRINGER HEIDELBERG | ko_KR |
dc.subject | Active electrode | ko_KR |
dc.subject | Unconstrained ECG measurement | ko_KR |
dc.subject | Capacitive ECG | ko_KR |
dc.subject | Flexible electrode | ko_KR |
dc.title | Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement | ko_KR |
dc.type | Article | ko_KR |
dc.contributor.AlternativeAuthor | 이승민 | - |
dc.contributor.AlternativeAuthor | 심교식 | - |
dc.contributor.AlternativeAuthor | 김고건 | - |
dc.contributor.AlternativeAuthor | 임용규 | - |
dc.contributor.AlternativeAuthor | 박광석 | - |
dc.identifier.doi | 10.1007/s11517-010-0597-y | - |
dc.citation.journaltitle | MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING | - |
dc.description.citedreference | Rantanen V, 2010, MED BIOL ENG COMPUT, V48, P39, DOI 10.1007/s11517-009-0565-6 | - |
dc.description.citedreference | Ji ZY, 2009, MED BIOL ENG COMPUT, V47, P1045, DOI 10.1007/s11517-009-0516-2 | - |
dc.description.citedreference | Szucs K, 2009, MED BIOL ENG COMPUT, V47, P487, DOI 10.1007/s11517-009-0485-5 | - |
dc.description.citedreference | Rissanen SM, 2008, MED BIOL ENG COMPUT, V46, P849, DOI 10.1007/s11517-008-0369-0 | - |
dc.description.citedreference | Ueno A, 2007, IEEE T BIO-MED ENG, V54, P759, DOI 10.1109/TBME.2006.889201 | - |
dc.description.citedreference | Lim YG, 2007, IEEE T BIO-MED ENG, V54, P718, DOI 10.1109/TBME.2006.889194 | - |
dc.description.citedreference | Lim YG, 2006, IEEE T BIO-MED ENG, V53, P956, DOI 10.1109/TBME.2006.872823 | - |
dc.description.citedreference | SEO JW, 2003, IEEE EMBS AS PAC C B | - |
dc.description.citedreference | SEO W, 2003, IEEE EMBS AS PAC C B | - |
dc.description.citedreference | ANDREONI G, 2000, ANN INT C IEEE EMBS | - |
dc.description.citedreference | GUYTON AC, 2000, TXB MED PHYSL, P107 | - |
dc.description.citedreference | TAMURA T, 1997, BIOMED INSTRUM TECHN, V31, P391 | - |
dc.description.citedreference | BAXTER LK, 1997, CAPACITIVE SENSORS D, P147 | - |
dc.description.citedreference | ISHIJIMA M, 1993, IEEE T BIO-MED ENG, V40, P593, DOI 10.1109/10.237680 | - |
dc.description.citedreference | REITZ JR, 1993, FDN ELECTROMAGNETIC, P141 | - |
dc.description.citedreference | VANRIJN ACM, 1990, MED BIOL ENG COMPUT, V28, P389 | - |
dc.description.citedreference | WINTER BB, 1983, IEEE T BIO-MED ENG, V30, P58 | - |
dc.description.citedreference | NEUMAN MR, 1978, MED INSTRUMENTATION | - |
dc.description.citedreference | LOPEZ A, 1969, IEEE T BIO-MED ENG, VBM16, P99 | - |
dc.description.tc | 1 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.