Publications

Detailed Information

Persistent Pure Ground-Glass Nodules in the Lung: Interscan Variability of Semiautomated Volume and Attenuation Measurements

DC Field Value Language
dc.contributor.authorPark, Chang Min-
dc.contributor.authorGoo, Jin Mo-
dc.contributor.authorLee, Hyun Ju-
dc.contributor.authorKim, Kwang Gi-
dc.contributor.authorShin, Yong Hwan-
dc.contributor.authorKang, Mi-Jin-
dc.date.accessioned2012-07-02T01:49:54Z-
dc.date.available2012-07-02T01:49:54Z-
dc.date.issued2010-12-
dc.identifier.citationAMERICAN JOURNAL OF ROENTGENOLOGY; Vol.195, no.6; W408-W414-
dc.identifier.issn0361-803X-
dc.identifier.urihttps://hdl.handle.net/10371/78046-
dc.description.abstractOBJECTIVE. The purpose of this article is to assess the interscan variability of semiautomated volume and attenuation measurements for pulmonary persistent pure ground-glass nodules. SUBJECTS AND METHODS. Thirty pure ground-glass nodules in 25 patients referred for known pure ground-glass nodules were evaluated with two consecutive unenhanced chest CT examinations performed within 10 minutes. For the second limited scan, patients were asked to first get off and then get back on the table to simulate a follow-up examination. CT images were reconstructed using two different algorithms (sharp, B60F; medium sharp, B50F). Two chest radiologists independently measured the volumes and attenuations of pure ground-glass nodules, twice on the first CT scan and once on the second CT scan, using commercial software. Interscan variability was measured using the Bland-Altman method. RESULTS. Nodule segmentation was successful in 98.3% (177/180) and 97.8% (176/180) of measurements with B60F and B50F, respectively. With respect to volume measurements, interscan variability for reviewer 1 was -17.7% to 18.3% with B60F and -18.8% to 15.7% with B50F; interscan variability for reviewer 2 was -18.6% to 18.9% with B60F and -15.6% to 17.2% with B50F. With respect to attenuation measurements, interscan variability for reviewer 1 was -7.2% to 7.9% with B60F and -7.9% to 9.4% with B50F; interscan variability for reviewer 2 was -7.7% to 8.1% with B60F and -8.5% to 9.9% for B50F. CONCLUSION. Variations in volume and attenuation measurements of persistent pure ground-glass nodules using commercial software were reasonably small, allowing the detection of clinically relevant growth.-
dc.language.isoen-
dc.publisherAMER ROENTGEN RAY SOC-
dc.subjectbronchoalveolar carcinoma-
dc.subjectpulmonary nodule-
dc.subjectlung cancer-
dc.subjectCT-
dc.subjectground-glass opacity-
dc.titlePersistent Pure Ground-Glass Nodules in the Lung: Interscan Variability of Semiautomated Volume and Attenuation Measurements-
dc.typeArticle-
dc.contributor.AlternativeAuthor박창민-
dc.contributor.AlternativeAuthor구진모-
dc.contributor.AlternativeAuthor이현주-
dc.contributor.AlternativeAuthor김광기-
dc.contributor.AlternativeAuthor강미진-
dc.contributor.AlternativeAuthor신용환-
dc.identifier.doi10.2214/AJR.09.4157-
dc.citation.journaltitleAMERICAN JOURNAL OF ROENTGENOLOGY-
dc.description.citedreferenceRavenel JG, 2008, RADIOLOGY, V247, P400, DOI 10.1148/radiol.2472070868-
dc.description.citedreferenceHansell DM, 2008, RADIOLOGY, V246, P697-
dc.description.citedreferenceGietema HA, 2007, RADIOLOGY, V245, P888, DOI 10.1148/radiol.2452061054-
dc.description.citedreferenceKim HY, 2007, RADIOLOGY, V245, P267, DOI 10.1148/radiol.2451061682-
dc.description.citedreferencePark CM, 2007, EUR RADIOL, V17, P2325, DOI 10.1007/s00330-007-0596-z-
dc.description.citedreferencePark CM, 2007, RADIOGRAPHICS, V27, P391, DOI 10.1148/rg.272065061-
dc.description.citedreferenceTsunezuka Y, 2007, WORLD J SURG, V31, P314, DOI 10.1007/s00268-006-0475-9-
dc.description.citedreferenceLee HJ, 2007, KOREAN J RADIOL, V8, P22-
dc.description.citedreference*NY EARL LUNG CANC, 2007, RADIOLOGY, V243, P239-
dc.description.citedreferenceHenschke CI, 2006, NEW ENGL J MED, V355, P1763-
dc.description.citedreferenceGoo JM, 2006, KOREAN J RADIOL, V7, P243-
dc.description.citedreferencePark CM, 2006, KOREAN J RADIOL, V7, P80-
dc.description.citedreferenceShimizu K, 2006, LUNG CANCER-J IASLC, V51, P173, DOI 10.1016/j.lungcan.2005.10.019-
dc.description.citedreferenceGoo JM, 2005, RADIOLOGY, V235, P850, DOI 10.1148/radiol.2353040737-
dc.description.citedreferenceManser RL, 2005, RESPIROLOGY, V10, P97-
dc.description.citedreferenceKostis WJ, 2004, RADIOLOGY, V231, P446, DOI 10.1148/radiol.2312030553-
dc.description.citedreferenceRevel MP, 2004, RADIOLOGY, V231, P459, DOI 10.1148/radiol.2312030241-
dc.description.citedreferenceWormanns D, 2004, EUR RADIOL, V14, P86, DOI 10.1007/s00330-003-2132-0-
dc.description.citedreferenceKakinuma R, 2004, J COMPUT ASSIST TOMO, V28, P17-
dc.description.citedreferenceKo JP, 2003, RADIOLOGY, V228, P864, DOI 10.1148/radiol.2283020059-
dc.description.citedreferenceNakata M, 2003, ANN THORAC SURG, V75, P1601-
dc.description.citedreferenceWiner-Muram HT, 2002, RADIOLOGY, V223, P798, DOI 10.1148/radiol.2233011026-
dc.description.citedreferenceHenschke CI, 2002, AM J ROENTGENOL, V178, P1053-
dc.description.citedreferenceNakata M, 2002, CHEST, V121, P1464-
dc.description.citedreferenceNakajima R, 2002, J COMPUT ASSIST TOMO, V26, P323, DOI 10.1097/01.RCT.0000016291.79954.36-
dc.description.citedreferenceKodama K, 2002, ANN THORAC SURG, V73, P386-
dc.description.citedreferenceAoki T, 2001, RADIOLOGY, V220, P803-
dc.description.citedreferenceHasegawa M, 2000, BRIT J RADIOL, V73, P1252-
dc.description.citedreferenceYankelevitz DF, 2000, RADIOLOGY, V217, P251-
dc.description.citedreferenceAoki T, 2000, AM J ROENTGENOL, V174, P763-
dc.description.citedreferenceHenschke CI, 1999, LANCET, V354, P99-
dc.description.citedreferenceSone S, 1998, LANCET, V351, P1242-
dc.description.citedreferenceBLAND JM, 1986, LANCET, V1, P307-
dc.description.tc1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share