Publications

Detailed Information

Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems

DC Field Value Language
dc.contributor.authorJin, Kwang Nam-
dc.contributor.authorPark, Chang Min-
dc.contributor.authorGoo, Jin Mo-
dc.contributor.authorLee, Hyun Ju-
dc.contributor.authorKim, Jung Im-
dc.contributor.authorKim, Hyo-Cheol-
dc.contributor.authorChoi, So Young-
dc.contributor.authorLee, Youkyung-
dc.date.accessioned2012-07-02T02:38:54Z-
dc.date.available2012-07-02T02:38:54Z-
dc.date.issued2010-09-
dc.identifier.citationEUROPEAN RADIOLOGY; Vol.20, no.9; 2108-2115ko_KR
dc.identifier.issn0938-7994-
dc.identifier.urihttps://hdl.handle.net/10371/78064-
dc.description.abstractTo describe our initial experience with percutaneous transthoracic biopsy (PCNB) of lung nodules using C-arm cone-beam CT (CBCT). Seventy-one consecutive patients with lung nodules of 30 mm or smaller underwent CBCT-guided PCNB using a coaxial cutting needle. We evaluated the procedure time, coaxial introducer dwell time, the numbers of pleural passages, coaxial introducer repositionings and CT acquisitions, as well as the technical success rate and radiation doses. Diagnostic accuracy, sensitivity, specificity and incidence of complications were also evaluated. PCNB was performed for 71 nodules: 63 solid, 6 part-solid and 2 ground-glass nodules. The procedure time, coaxial introducer dwell time, numbers of pleural passages, coaxial introducer repositionings and CT acquisitions were 17.9 +/- 5.9 min, 8.7 +/- 3.8 min, 1.1 +/- 0.4, 0.2 +/- 0.5 and 2.9 +/- 0.7, respectively. The technical success rate was 100% and the radiation dose was 272 +/- 116 mGy. Thirty-six nodules (50.7%) were diagnosed as malignant, 25 (35.2%) as benign and 10 (14.1%) as indeterminate. Diagnostic accuracy, sensitivity, specificity and incidence of complications were 98.4%, 97%, 100% and 38%, respectively. Complications included pneumothorax in 18 patients (25.4%), haemoptysis in 10 (14.1%) and chest pain in one (1.4%). Under CBCT guidance, PCNB of lung nodules can be performed accurately, providing both real-time fluoroscopic guidance and CT imaging capabilities.ko_KR
dc.language.isoenko_KR
dc.publisherSPRINGERko_KR
dc.subjectBiopsyko_KR
dc.subjectLung noduleko_KR
dc.subjectPercutaneous transthoracicko_KR
dc.subjectC-arm cone-beam CTko_KR
dc.subjectComputed tomographyko_KR
dc.titleInitial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systemsko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor진광남-
dc.contributor.AlternativeAuthor박창민-
dc.contributor.AlternativeAuthor구진모-
dc.contributor.AlternativeAuthor이현주-
dc.contributor.AlternativeAuthor이유경-
dc.contributor.AlternativeAuthor김정임-
dc.contributor.AlternativeAuthor최소영-
dc.contributor.AlternativeAuthor김효철-
dc.identifier.doi10.1007/s00330-010-1783-x-
dc.citation.journaltitleEUROPEAN RADIOLOGY-
dc.description.citedreferenceKim HC, 2009, J VASC INTERV RADIOL, V20, P888-
dc.description.citedreferenceMiracle AC, 2009, AM J NEURORADIOL, V30, P1088, DOI 10.3174/ajnr.A1653-
dc.description.citedreferenceFRANK K, 2009, INTERVENTIONS USING, P370-
dc.description.citedreferenceReichardt B, 2008, SKELETAL RADIOL, V37, P1069, DOI 10.1007/s00256-008-0473-0-
dc.description.citedreferenceGupta R, 2008, RADIOGRAPHICS, V28, P2009, DOI 10.1148/rg.287085004-
dc.description.citedreferenceWallace MJ, 2008, J VASC INTERV RADIOL, V19, P799, DOI 10.1016/j.jvir.2008.02.018-
dc.description.citedreferenceSCARFE WC, 2008, DENT CLIN N AM, V52, P707-
dc.description.citedreferenceRivera MP, 2007, CHEST, V132, p131S, DOI 10.1378/chest.07-1357-
dc.description.citedreferenceHirota S, 2006, CARDIOVASC INTER RAD, V29, P1034, DOI 10.1007/s00270-005-0287-6-
dc.description.citedreferenceRafferty MA, 2005, LARYNGOSCOPE, V115, P2138, DOI 10.1097/01.mlg.0000180759.52082.45-
dc.description.citedreferenceCarlson SK, 2005, RADIOLOGY, V237, P701, DOI 10.1148/radiol.2372041323-
dc.description.citedreferenceGupta S, 2005, RADIOLOGY, V234, P631, DOI 10.1148/radiol.2342031423-
dc.description.citedreferenceYeow KM, 2004, CHEST, V126, P748-
dc.description.citedreferenceGeraghty PR, 2003, RADIOLOGY, V229, P475-
dc.description.citedreferenceOhno Y, 2003, AM J ROENTGENOL, V180, P1665-
dc.description.citedreferenceCarlson SK, 2001, RADIOLOGY, V219, P515-
dc.description.citedreferenceKo JP, 2001, RADIOLOGY, V218, P491-
dc.description.citedreferenceTsukada H, 2000, AM J ROENTGENOL, V175, P239-
dc.description.citedreferenceLaurent F, 2000, CLIN RADIOL, V55, P281-
dc.description.citedreferenceYankelevitz DE, 2000, RADIOL CLIN N AM, V38, P267-
dc.description.citedreferenceDaly B, 1999, RADIOLOGY, V211, P309-
dc.description.citedreferenceMoore EH, 1998, RADIOLOGY, V208, P303-
dc.description.citedreferenceSwischuk JL, 1998, J VASC INTERV RADIOL, V9, P347-
dc.description.citedreferenceKato R, 1996, RADIOLOGY, V201, P576-
dc.description.citedreferenceKazerooni EA, 1996, RADIOLOGY, V198, P371-
dc.description.citedreferenceMILLER KS, 1988, CHEST, V93, P742-
dc.description.tc5-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share