Publications
Detailed Information
Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jin, Kwang Nam | - |
dc.contributor.author | Park, Chang Min | - |
dc.contributor.author | Goo, Jin Mo | - |
dc.contributor.author | Lee, Hyun Ju | - |
dc.contributor.author | Kim, Jung Im | - |
dc.contributor.author | Kim, Hyo-Cheol | - |
dc.contributor.author | Choi, So Young | - |
dc.contributor.author | Lee, Youkyung | - |
dc.date.accessioned | 2012-07-02T02:38:54Z | - |
dc.date.available | 2012-07-02T02:38:54Z | - |
dc.date.issued | 2010-09 | - |
dc.identifier.citation | EUROPEAN RADIOLOGY; Vol.20, no.9; 2108-2115 | ko_KR |
dc.identifier.issn | 0938-7994 | - |
dc.identifier.uri | https://hdl.handle.net/10371/78064 | - |
dc.description.abstract | To describe our initial experience with percutaneous transthoracic biopsy (PCNB) of lung nodules using C-arm cone-beam CT (CBCT). Seventy-one consecutive patients with lung nodules of 30 mm or smaller underwent CBCT-guided PCNB using a coaxial cutting needle. We evaluated the procedure time, coaxial introducer dwell time, the numbers of pleural passages, coaxial introducer repositionings and CT acquisitions, as well as the technical success rate and radiation doses. Diagnostic accuracy, sensitivity, specificity and incidence of complications were also evaluated. PCNB was performed for 71 nodules: 63 solid, 6 part-solid and 2 ground-glass nodules. The procedure time, coaxial introducer dwell time, numbers of pleural passages, coaxial introducer repositionings and CT acquisitions were 17.9 +/- 5.9 min, 8.7 +/- 3.8 min, 1.1 +/- 0.4, 0.2 +/- 0.5 and 2.9 +/- 0.7, respectively. The technical success rate was 100% and the radiation dose was 272 +/- 116 mGy. Thirty-six nodules (50.7%) were diagnosed as malignant, 25 (35.2%) as benign and 10 (14.1%) as indeterminate. Diagnostic accuracy, sensitivity, specificity and incidence of complications were 98.4%, 97%, 100% and 38%, respectively. Complications included pneumothorax in 18 patients (25.4%), haemoptysis in 10 (14.1%) and chest pain in one (1.4%). Under CBCT guidance, PCNB of lung nodules can be performed accurately, providing both real-time fluoroscopic guidance and CT imaging capabilities. | ko_KR |
dc.language.iso | en | ko_KR |
dc.publisher | SPRINGER | ko_KR |
dc.subject | Biopsy | ko_KR |
dc.subject | Lung nodule | ko_KR |
dc.subject | Percutaneous transthoracic | ko_KR |
dc.subject | C-arm cone-beam CT | ko_KR |
dc.subject | Computed tomography | ko_KR |
dc.title | Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems | ko_KR |
dc.type | Article | ko_KR |
dc.contributor.AlternativeAuthor | 진광남 | - |
dc.contributor.AlternativeAuthor | 박창민 | - |
dc.contributor.AlternativeAuthor | 구진모 | - |
dc.contributor.AlternativeAuthor | 이현주 | - |
dc.contributor.AlternativeAuthor | 이유경 | - |
dc.contributor.AlternativeAuthor | 김정임 | - |
dc.contributor.AlternativeAuthor | 최소영 | - |
dc.contributor.AlternativeAuthor | 김효철 | - |
dc.identifier.doi | 10.1007/s00330-010-1783-x | - |
dc.citation.journaltitle | EUROPEAN RADIOLOGY | - |
dc.description.citedreference | Kim HC, 2009, J VASC INTERV RADIOL, V20, P888 | - |
dc.description.citedreference | Miracle AC, 2009, AM J NEURORADIOL, V30, P1088, DOI 10.3174/ajnr.A1653 | - |
dc.description.citedreference | FRANK K, 2009, INTERVENTIONS USING, P370 | - |
dc.description.citedreference | Reichardt B, 2008, SKELETAL RADIOL, V37, P1069, DOI 10.1007/s00256-008-0473-0 | - |
dc.description.citedreference | Gupta R, 2008, RADIOGRAPHICS, V28, P2009, DOI 10.1148/rg.287085004 | - |
dc.description.citedreference | Wallace MJ, 2008, J VASC INTERV RADIOL, V19, P799, DOI 10.1016/j.jvir.2008.02.018 | - |
dc.description.citedreference | SCARFE WC, 2008, DENT CLIN N AM, V52, P707 | - |
dc.description.citedreference | Rivera MP, 2007, CHEST, V132, p131S, DOI 10.1378/chest.07-1357 | - |
dc.description.citedreference | Hirota S, 2006, CARDIOVASC INTER RAD, V29, P1034, DOI 10.1007/s00270-005-0287-6 | - |
dc.description.citedreference | Rafferty MA, 2005, LARYNGOSCOPE, V115, P2138, DOI 10.1097/01.mlg.0000180759.52082.45 | - |
dc.description.citedreference | Carlson SK, 2005, RADIOLOGY, V237, P701, DOI 10.1148/radiol.2372041323 | - |
dc.description.citedreference | Gupta S, 2005, RADIOLOGY, V234, P631, DOI 10.1148/radiol.2342031423 | - |
dc.description.citedreference | Yeow KM, 2004, CHEST, V126, P748 | - |
dc.description.citedreference | Geraghty PR, 2003, RADIOLOGY, V229, P475 | - |
dc.description.citedreference | Ohno Y, 2003, AM J ROENTGENOL, V180, P1665 | - |
dc.description.citedreference | Carlson SK, 2001, RADIOLOGY, V219, P515 | - |
dc.description.citedreference | Ko JP, 2001, RADIOLOGY, V218, P491 | - |
dc.description.citedreference | Tsukada H, 2000, AM J ROENTGENOL, V175, P239 | - |
dc.description.citedreference | Laurent F, 2000, CLIN RADIOL, V55, P281 | - |
dc.description.citedreference | Yankelevitz DE, 2000, RADIOL CLIN N AM, V38, P267 | - |
dc.description.citedreference | Daly B, 1999, RADIOLOGY, V211, P309 | - |
dc.description.citedreference | Moore EH, 1998, RADIOLOGY, V208, P303 | - |
dc.description.citedreference | Swischuk JL, 1998, J VASC INTERV RADIOL, V9, P347 | - |
dc.description.citedreference | Kato R, 1996, RADIOLOGY, V201, P576 | - |
dc.description.citedreference | Kazerooni EA, 1996, RADIOLOGY, V198, P371 | - |
dc.description.citedreference | MILLER KS, 1988, CHEST, V93, P742 | - |
dc.description.tc | 5 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count