Publications

Detailed Information

Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty

Cited 25 time in Web of Science Cited 24 time in Scopus
Authors

Kim, Tae Kyun; Chang, Chong Bum; Kang, Yeon Gwi; Chung, Byung June; Seong, Sang Cheol; Cho, Hyung Joon

Issue Date
2010-01
Publisher
ELSEVIER SCIENCE BV
Citation
KNEE; Vol.17(1); 23-28
Keywords
Total knee arthroplastyAccuracyCement fixationComputer assisted navigationBone resections
Abstract
While computer assisted total knee arthroplasty (TKA) has been documented to increase the surgical accuracy in the planning process, there is little information about the accuracy in execution processes. We aimed to determine the accuracy of execution processes for bone resections and implant fixation in TKAs performed with the techniques of computer assisted navigation and minimally invasive surgery. Execution deviations, defined as the differences between planned targets and executed results, were evaluated for bone resections and implant fixation in 107 TKAs. In tibia resection, the mean resection thickness, coronal alignment, and sagittal alignment were 0.2 mm smaller, 0.3 degrees more valgus, 0.3 degrees less posterior slope than the planned, respectively. In femur resection, the mean resection thicknesses in the medial and lateral femoral condyles, coronal alignment, and sagittal alignment were 0.6 mm smaller, 0.8 mm smaller, 0.1 degrees more varus, and 0.7 degrees less posterior slope than the planned, respectively. In implant fixation, the mean coronal alignment and degree of extension was 0.7 degrees more valgus and 1.6 degrees decrease than the planned, respectively. Only the occurrence of unacceptable executions in implant fixation had significant effects on the final coronal alignment. The density of a bone and the quality of saw blade had significant effect on the accuracy of bone resections. Execution deviations from planned alignment commonly occur in computer-assisted minimally invasive TKA, resulting typically from the techniques of bone resections and implant fixation, and this information should be considered to improve the surgical accuracy of navigated TKAs.
ISSN
0968-0160
Language
English
URI
https://hdl.handle.net/10371/78454
DOI
https://doi.org/10.1016/j.knee.2009.06.004