Publications

Detailed Information

Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome

DC Field Value Language
dc.contributor.authorKang, Sung Eun-
dc.contributor.authorLee, Joon Woo-
dc.contributor.authorKim, Joo Hyung-
dc.contributor.authorPark, Kun Woo-
dc.contributor.authorYeom, Jin S.-
dc.contributor.authorKang, Heung Sik-
dc.creator염진섭-
dc.date.accessioned2013-01-25T06:24:40Z-
dc.date.available2013-01-25T06:24:40Z-
dc.date.issued2011-04-
dc.identifier.citationSKELETAL RADIOLOGY Vol.40 No.4, pp. 453-460-
dc.identifier.issn0364-2348-
dc.identifier.urihttps://hdl.handle.net/10371/81099-
dc.description.abstractSacroplasty for sacral insufficiency fractures (SIFs) has been performed mostly under computed tomography (CT) or fluoroscopy guidance. The purposes of this study are to describe technical tips and clinical outcomes of sacroplasty under C-arm flat panel detector CT (C-arm CT) guidance, and to compare the cement distributions shown on C-arm CT with those on multi-detector CT (MDCT).This study consisted of patients who underwent sacroplasty for SIF using C-arm CT from May 2006 to May 2009. Technical success was assessed in terms of cement filling and leakage. Clinical outcome was assessed at short-term (less than 1 month) and long-term (more than 1 month) follow-up using a four-grade patient satisfaction scale: poor, fair, good, and excellent. After sacroplasty, all patients underwent MDCT and three radiologists compared MDCT images with C-arm CT images in consensus, focusing on the cement distribution and cement leakage.Sacroplasties were performed on both sacral alae in all 8 patients (male:female = 2:6, mean age = 76.9, range = 63-82). The technical success rate was 100%. At short-term follow up, 6 patients (87.5%) reported significant improvement. Five patients (62.5%) were available for long-term follow-up and all 5 patients reported a reduced pain and an improved ability to ambulate. Using MDCT as the standard of reference, the cement distribution was visualized equally well by C-arm CT.Sacroplasty under C-arm CT showed excellent technical success and good clinical outcome. There was an excellent correlation between C-arm CT and MDCT in evaluating cement distribution and cement leakage.en
dc.language.isoenen
dc.publisherSPRINGERen
dc.subject복합학en
dc.subjectSacroplasty-
dc.subjectSacral insufficiency fracture-
dc.subjectC-arm flat-panel detector CT-
dc.subjectC-arm CT-
dc.subjectCement distribution-
dc.titlePercutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcomeen
dc.typeArticle-
dc.contributor.AlternativeAuthor강성은-
dc.contributor.AlternativeAuthor이준우-
dc.contributor.AlternativeAuthor김주형-
dc.contributor.AlternativeAuthor박근우-
dc.contributor.AlternativeAuthor염진섭-
dc.contributor.AlternativeAuthor강흥식-
dc.identifier.doi10.1007/s00256-010-0959-4-
dc.description.srndOAIID:oai:osos.snu.ac.kr:snu2011-01/102/0000004226/2-
dc.description.srndSEQ:2-
dc.description.srndPERF_CD:SNU2011-01-
dc.description.srndEVAL_ITEM_CD:102-
dc.description.srndUSER_ID:0000004226-
dc.description.srndADJUST_YN:Y-
dc.description.srndEMP_ID:A076317-
dc.description.srndDEPT_CD:801-
dc.description.srndCITE_RATE:1.541-
dc.description.srndFILENAME:E030T_SkeletalRadiol-2011_Kang_Percutaneous sacroplasty with the use.pdf-
dc.description.srndDEPT_NM:의학과-
dc.description.srndEMAIL:highcervical@gmail.com-
dc.description.srndSCOPUS_YN:Y-
dc.description.srndCONFIRM:Y-
dc.identifier.srnd2011-01/102/0000004226/2-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share