Publications

Detailed Information

Optimization of acquisition parameters of diffusion-tensor magnetic resonance imaging in the spinal cord.

DC Field Value Language
dc.contributor.authorLee, Joon Woo-
dc.contributor.authorKim, Jae Hyung-
dc.contributor.authorKang, Heung Sik-
dc.contributor.authorLee, Jong Sea-
dc.contributor.authorChoi, Ja-Young-
dc.contributor.authorYeom, Jin-Sup-
dc.contributor.authorKim, Hyun-Jib-
dc.contributor.authorChung, Hye Won-
dc.creator염진섭-
dc.date.accessioned2013-04-02T02:04:20Z-
dc.date.available2013-04-02T02:04:20Z-
dc.date.issued2006-07-
dc.identifier.citationINVESTIGATIVE RADIOLOGY Vol.41 No.7, pp. 553-559-
dc.identifier.issn0020-9996-
dc.identifier.urihttps://hdl.handle.net/10371/81621-
dc.description.abstractObjective: The purpose of this study was to optimize imaging parameters for diffusion tensor imaging (DTI) of the cervical spinal cord using a recently developed sensitivity-encoded (SENSE) imaging technique, which can substantially reduce susceptibility artifacts.Conclusion: Optimal parameters for DTI in the cervical spinal cordincluded a b-value of 900 secondsmm2, 15 diffusion gradient directions, 5 excitations, and a slice thickness of 4mm.en
dc.language.isoenen
dc.publisherLIPPINCOTT WILLIAMS & WILKINSen
dc.subject의약학en
dc.subjectmagnetic resonance imagingen
dc.subjectdiffusion tensor
imaging
-
dc.subjectspinal cord-
dc.titleOptimization of acquisition parameters of diffusion-tensor magnetic resonance imaging in the spinal cord.en
dc.typeArticleen
dc.contributor.AlternativeAuthor이준우-
dc.contributor.AlternativeAuthor김재형-
dc.contributor.AlternativeAuthor강흥식-
dc.contributor.AlternativeAuthor이종세-
dc.contributor.AlternativeAuthor최자영-
dc.contributor.AlternativeAuthor염진섭-
dc.contributor.AlternativeAuthor김현집-
dc.contributor.AlternativeAuthor정혜원-
dc.description.srndOAIID:oai:osos.snu.ac.kr:snu2006-01/102/0000004226/1-
dc.description.srndSEQ:1-
dc.description.srndPERF_CD:SNU2006-01-
dc.description.srndEVAL_ITEM_CD:102-
dc.description.srndUSER_ID:0000004226-
dc.description.srndADJUST_YN:N-
dc.description.srndEMP_ID:A076317-
dc.description.srndDEPT_CD:801-
dc.description.srndCITE_RATE:3.398-
dc.description.srndFILENAME:E007T_InvestRadiol-2006_Lee_Optimization of acquisition parameters of diffusion.pdf-
dc.description.srndDEPT_NM:의학과-
dc.description.srndEMAIL:highcervical@gmail.com-
dc.description.srndCONFIRM:Y-
dc.description.srndCONFIRM:Y-
dc.identifier.srnd2006-01/102/0000004226/1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share