Publications

Detailed Information

Radiofrequency ablation in the liver using two cooled-wet electrodes in the bipolar mode

DC Field Value Language
dc.contributor.authorLee, Jeong Min-
dc.contributor.authorHan, Joon Koo-
dc.contributor.authorKim, Se Hyung-
dc.contributor.authorLee, Jae Young-
dc.contributor.authorPark, Hee Sun-
dc.contributor.authorEo, Hong-
dc.contributor.authorChoi, Byung Ihn-
dc.date.accessioned2009-10-05T04:05:13Z-
dc.date.available2009-10-05T04:05:13Z-
dc.date.issued2005-04-13-
dc.identifier.citationEur Radiol 15:2163–2170en
dc.identifier.issn0938-7994 (Print)-
dc.identifier.issn1432-1084 (Electronic)-
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=15827727-
dc.identifier.urihttps://hdl.handle.net/10371/10071-
dc.description.abstractThe purpose of this study was to demonstrate the efficacy of bipolar radiofrequency ablation (RFA) using cooled-wet electrodes inducing coagulation in ex vivo bovine livers and in in vivo canine livers. In ex vivo experiments, 20 coagulations were created by monopolar (group A), and bipolar RFA (group B) using a 200 W generator (Valleylab) and one or two cooled-wet electrodes. In in vivo experiments, one coagulation was created by bipolar RFA in each of eight dogs via laparotomy. In ex vivo and in vivo experiments, RF was applied to one or two electrodes at 100 W for 10 min. The dimensions of the coagulations were compared in the two groups. In ex vivo experiments, the mean volumes of the coagulations produced in group B (54.0+/-16.5 cm3) were greater than those produced in group A (33.9+/-12.7 cm3) (P=0.007). In in vivo experiments, bipolar RFA produced a coagulation of 39.4+/-15.6 cm3 without a major complication. The present study showed that a RF electrode system using two cooled-wet electrodes in the bipolar mode created larger coagulation volumes than the monopolar mode, and this system can be used to create large coagulation without major complications.en
dc.description.sponsorshipThis study was supported
by grant No. 04-2004-046-0 from the Seoul National University
Hospital Research Fund.
en
dc.language.isoenen
dc.publisherSpringer Verlagen
dc.subjectAnimalsen
dc.subjectLiveren
dc.subjectInterventional proceduresen
dc.subjectRadiofrequency ablationen
dc.subjectExperimental studiesen
dc.titleRadiofrequency ablation in the liver using two cooled-wet electrodes in the bipolar modeen
dc.typeArticleen
dc.contributor.AlternativeAuthor이정민-
dc.contributor.AlternativeAuthor한준구-
dc.contributor.AlternativeAuthor김세형-
dc.contributor.AlternativeAuthor이재영-
dc.contributor.AlternativeAuthor박희선-
dc.contributor.AlternativeAuthor오홍-
dc.contributor.AlternativeAuthor최병인-
dc.identifier.doi10.1007/s00330-005-2713-1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share