Publications

Detailed Information

A Calibration Technique for a Redundant IMU Containing Low-Grade Inertial Sensors

Cited 43 time in Web of Science Cited 67 time in Scopus
Authors

Cho, Seong Yun; Park, Chan Gook

Issue Date
2005
Publisher
ETRI
Citation
ETRI Journal, vol. 27, no. 4, pp. 418-426
Keywords
Calibrationcone configuration redundant IMUrate testmulti-position test
Abstract
A calibration technique for a redundant inertial measurement unit (IMU) containing low-grade inertial sensors is proposed. In order to calibrate a redundant IMU that can detect and isolate faulty sensors, the fundamental coordinate frames in the IMU are defined and the IMU error is modeled based on the frames. Equations to estimate the error coefficients of the redundant IMU are formulated, and a test sequence using a 2-axis turntable is also presented. Finally, a redundant IMU with cone configuration is implemented using low-grade inertial sensors, and the performance of the proposed technique is verified experimentally.
ISSN
1225-6463
Language
English
URI
https://hdl.handle.net/10371/10147
DOI
https://doi.org/10.4218/etrij.05.0104.0191
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.