Publications

Detailed Information

Collateral Ventilation Quantification Using Xenon-enhanced Dynamic Dual Energy CT : 제논 조영증강 동적 이중에너지 CT를 이용한 측부 환기량 정량화

DC Field Value Language
dc.contributor.advisor구진모-
dc.contributor.authorEun-Ah Park-
dc.date.accessioned2017-07-14T01:25:48Z-
dc.date.available2017-07-14T01:25:48Z-
dc.date.issued2014-02-
dc.identifier.other000000016579-
dc.identifier.urihttps://hdl.handle.net/10371/121946-
dc.description학위논문 (박사)-- 서울대학교 대학원 : 의학과, 2014. 2. 구진모.-
dc.description.abstractPurpose: This study was conducted to evaluate whether the difference in the degree of collateral ventilation between canine and swine models of bronchial obstruction can be detected using xenon-enhanced, dynamic dual energy technique of dual source CT. Through this study, we wanted to evaluate the feasibility of xenon-enhanced, dynamic dual energy technique of dual source CT for the quantification of collateral ventilation.
Methods: Eight adult Mongrel dogs (25~30 kg) and six pigs (25~30kg) were studied under general anesthesia. With fluoroscopic guidance, the posterior segmental bronchus of the caudal lobe was occluded with 11.5 mm standard occlusion balloon catheter. Dynamic dual energy scanning (51 eff. mAs/213 eff. mAs at 140 kV/80 kV) was performed with dual source CT (Somatom Definition, Siemens) at a 12-second interval for 2 minute washin period and 24-second interval for 3 minute washout period while animals were mechanically ventilated via an endotracheal tube (60% xenon). CT images and xenon maps were generated using dedicated software. Ventilation parameters of magnitude (A value), maximal slope, velocity (K value), and time-to-peak enhancement (TTP) were calculated from dynamic xenon map using exponential function of Kety model.
Results: Pigs showed significant lower maximal enhancement in the occluded than in the patent parenchyma (8.3 ± 1.1 HU vs. 41.3 ± 5.9 HU, p =0.027) but dogs did not show any difference (44.4 ± 8.1 HU vs. 47.2 ± 6.0 HU, p =0.123). Bigger between-parenchyma difference in A value was observed in pigs than in dogs (absolute difference, -33.0 ± 5.0 HU vs. -2.8 ± 7.1 HU, p =0.001
-
dc.description.abstractnormalized percentage difference, -79.8 ± 1.8% vs. -5.4 ± 16.4%, p =0.0007). Mean values of maximal slopes in both periods significantly decreased in the occluded parenchyma only in pigs (maximal slopewashin, 4.7 ± 1.9 vs. 6.3 ± 2.8 in dogs, p =0.068-
dc.description.abstractmaximal slopewashout, -10.6 ± 2.8 vs. -8.6 ± 2.8 in dogs, p =0.092-
dc.description.abstractmaximal slopewashin, 1.0 ± 0.2 vs. 5.1 ± 1.5 in pigs, p =0.027-
dc.description.abstractmaximal slopewashout, -1.6 ± 1.4 vs. -10.2 ± 1.7 in pigs, p =0.028). Between-parenchyma absolute and normalized percentage differences in maximal slopes were greater in pigs than in dogs but statistical difference reached only in the washin period (all, p <0.05). K values of both periods were not different in dogs (p =0.892). One the other hand, in pigs, significant difference was found only in washin period (0.0029 ± 0.0006 sec-1 for occluded vs. 0.0039 ± 0.0003 sec-1for patent, p =0.027). While TTP was not significantly different between the occluded and patent parenchyma in dogs (p =0.892), TTP was markedly delayed in the occluded parenchyma in pigs (absolute difference, 212 ± 53.5 s vs. 140 ± 9.8 s, p =0.027-
dc.description.abstractnormalized percentage difference, 51.1 ± 34.4% vs. 6.8 ± 33.5%, p =0.013).
Conclusions: Xenon-enhanced, dynamic dual energy technique of dual source CT allows quantifying collateral ventilation and detecting its difference between canine and swine models of bronchial obstruction.
-
dc.description.tableofcontentsCONTENTS
Abstract i
Contents iv
List of tables v
List of figures vi
List of abbreviations vii

Introduction 1
Material and Methods 6
Results 15
Discussion 36

References 44
Abstract in Korean 55
-
dc.formatapplication/pdf-
dc.format.extent1982777 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subjectChronic obstructive pulmonary disease-
dc.subjectEmphysema-
dc.subjectCollateral ventilation-
dc.subjectXenon-
dc.subjectDual energy CT-
dc.subject.ddc610-
dc.titleCollateral Ventilation Quantification Using Xenon-enhanced Dynamic Dual Energy CT-
dc.title.alternative제논 조영증강 동적 이중에너지 CT를 이용한 측부 환기량 정량화-
dc.typeThesis-
dc.contributor.AlternativeAuthor박은아-
dc.description.degreeDoctor-
dc.citation.pagesvii, 55-
dc.contributor.affiliation의과대학 의학과-
dc.date.awarded2014-02-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share