Browse

Filling Quality of MTA Canal Obturation in Type Ⅲ Root Canal with Isthmus

DC Field Value Language
dc.contributor.advisor금기연-
dc.contributor.author오소람-
dc.date.accessioned2017-07-14T05:43:59Z-
dc.date.available2017-07-14T05:43:59Z-
dc.date.issued2016-02-
dc.identifier.other000000132493-
dc.identifier.urihttps://hdl.handle.net/10371/125099-
dc.description학위논문 (박사)-- 서울대학교 대학원 : 치의학대학원 치의과학과 치과보존학전공, 2016. 2. 금기연.-
dc.description.abstractObjectives
The objective of this study was to compare the filling quality of mineral trioxide aggregate (MTA) canal obturation with lateral compaction (LC) and continuous wave of condensation (CW) in type III mesial root canals with isthmuses of the mandibular first molars using micro-computed tomography (micro-CT). The null hypothesis was that there is no significant difference in filling quality among the three obturation techniques in the main root canals and the isthmus.

Materials and Methods
The mesial roots of 60 extracted human mandibular first molars with type Ⅲ canal configuration by Weine that had an interconnecting isthmus were prepared to an apical size of #40. The specimens were allocated into three groups of 20 roots for obturation by either LC or CW using a gutta-percha and AH Plus sealer, or by MTA canal obturation with OrthoMTA (MTA). The obturated roots were scanned by micro-CT (Skyscan 1172). The filled volume ratio (%) in the main canal or in the isthmus at the apical third was calculated using CTAn software. The filled volume ratio was defined as the ratio of the sum of the obturated gutta-percha and sealer volume or MTA to the main canal or isthmus volume. Data were statistically analyzed using the Kruskal-Wallis test or Mann-Whitney U test applying a significance level of 0.05.

Results
Reconstructive micro-CT images demonstrated that the LC group had lower filling densities in the isthmus than either CW or MTA. Unfilled radiolucent voids were shown in two samples in the MTA group. The filled volume ratio was not significantly different among the three groups for the main canals (p > 0.05). In the isthmus, the filled volume ratio for LC was lower than in CW and MTA (p < 0.05). The volume ratio of the gutta-percha for LC was significantly lower in the isthmus than that of CW, whereas the volume ratio of the sealer was significantly greater (p < 0.05).

Conclusions
MTA canal obturation showed comparable filling quality to LC or CW techniques in the main canal or isthmus.
-
dc.description.tableofcontentsI. Introduction 1

II. Materials and Methods 5
Sample selection and root canal preparation 5
Root canal obturation 6
LC group (n=20) 7
CW group (n=20) 7
MTA group (n=20) 8
Micro-CT scanning and image reconstruction 9

III. Results 11

Ⅳ. Discussion 13

Ⅴ. Conclusions 15

Ⅵ. References 17

Table 23

Figure 27

국문초록 41
-
dc.formatapplication/pdf-
dc.format.extent2022489 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subjectMTA canal obturation-
dc.subjectFilled volume ratio-
dc.subjectIsthmus-
dc.subjectMicro-computed tomography-
dc.subjectMandibular first molar-
dc.subjectType III canal-
dc.subject.ddc617-
dc.titleFilling Quality of MTA Canal Obturation in Type Ⅲ Root Canal with Isthmus-
dc.typeThesis-
dc.description.degreeDoctor-
dc.citation.pages42-
dc.contributor.affiliation치의학대학원 치의과학과-
dc.date.awarded2016-02-
Appears in Collections:
College of Dentistry/School of Dentistry (치과대학/치의학대학원)Dept. of Dental Science(치의과학과)Theses (Ph.D. / Sc.D._치의과학과)
Files in This Item:
  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.