Publications
Detailed Information
The Efficacy of Noninvasive Hemoglobin Measurement by Pulse CO-Oximetry in Neonates : 신생아에서 Pulse CO-Oximetry를 통해 비침습적으로 측정한 혈색소의 유효성
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | 김한석 | - |
dc.contributor.author | 정영화 | - |
dc.date.accessioned | 2017-07-19T10:10:59Z | - |
dc.date.available | 2017-07-19T10:10:59Z | - |
dc.date.issued | 2014-02 | - |
dc.identifier.other | 000000016600 | - |
dc.identifier.uri | https://hdl.handle.net/10371/132380 | - |
dc.description | 학위논문 (석사)-- 서울대학교 대학원 : 임상의과학과, 2014. 2. 김한석. | - |
dc.description.abstract | Objective: To evaluate clinical applicability of noninvasive hemoglobin (Hb) measurement with a pulse CO-oximetry in neonates.
Materials and Methods: We conducted a prospective study for preterm or term neonates admitted to NICU of Seoul National University Childrens Hospital, Seoul, Korea. After IRB approval and informed consents from their parents, 56 neonates were enrolled in the study. Hb measurements by the Masimo Radical-7TM (Rainbow Pulse CO-Oximeter®, Masimo Corp., Irvine, CA, USA) were recorded just prior to venous samplings and the collected data was compared with the corresponding venous Hb value by laboratory test. Results: The collected data were com¬pared with the corresponding venous Hb level obtained in laboratory testing, and a total of 137 data pairs were analyzed. Noninvasive Hb values measured with a pulse CO-Oximetry were significantly cor¬related with the venous Hb levels (correlation coefficient, r = .758 | - |
dc.description.abstract | p < .001). Hb values measured with a pulse CO-Oximetry were higher than those measured with a laboratory hematology analyzer (13.3 ± 2.6 g/dL vs. 12.5 ± 3.1 g/dL). In terms of the agreement be¬tween the laboratory analyzer and the pulse CO-oximetry, 94.8% of the measurements fell within two standard deviations of the mean difference.
Conclusion: Noninvasive Hb measurements with pulse CO-Oximetry provide clinically acceptable accuracy, and they were significantly correlated with laboratory Hb measurement in neonates. In terms of the clinical applicability, noninvasive Hb monitoring with a pulse CO-Oximetry could be useful in the early detection of Hb changes in neonates. Keywords : hemoglobin | - |
dc.description.abstract | hemoglobinopathy | - |
dc.description.abstract | monitoring | - |
dc.description.abstract | neonatal intensive care | - |
dc.description.abstract | premature infant
Student Number : 2012-22727 | - |
dc.description.tableofcontents | Abstract i
Contents iii List of tables and figures iv Introduction 2 Materials and Methods 3 Results 5 Discussion 11 References 14 Abstract in Korean 16 | - |
dc.format | application/pdf | - |
dc.format.extent | 897391 bytes | - |
dc.format.medium | application/pdf | - |
dc.language.iso | en | - |
dc.publisher | 서울대학교 대학원 | - |
dc.subject.ddc | 610 | - |
dc.title | The Efficacy of Noninvasive Hemoglobin Measurement by Pulse CO-Oximetry in Neonates | - |
dc.title.alternative | 신생아에서 Pulse CO-Oximetry를 통해 비침습적으로 측정한 혈색소의 유효성 | - |
dc.type | Thesis | - |
dc.contributor.AlternativeAuthor | Jung Young Hwa | - |
dc.description.degree | Master | - |
dc.citation.pages | iv, 16 | - |
dc.contributor.affiliation | 의과대학 임상의과학과 | - |
dc.date.awarded | 2014-02 | - |
- Appears in Collections:
- Files in This Item:
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.