Intraocular Pressure Measurement with a Rebound Tonometer (TonoVet®) in Normal Pigeons

DC Field Value Language
dc.contributor.advisor서강문-
dc.contributor.author임재국-
dc.date.accessioned2017-10-31T08:18:35Z-
dc.date.available2017-10-31T08:18:35Z-
dc.date.issued2017-08-
dc.identifier.other000000145572-
dc.identifier.urihttps://hdl.handle.net/10371/137921-
dc.description학위논문 (석사)-- 서울대학교 대학원 수의과대학 수의학과, 2017. 8. 서강문.-
dc.description.abstractThe purpose of this study was to evaluate the applicability of a rebound tonometer (TonoVet®) in pigeon eyes and to establish normal reference intraocular pressure (IOP) values in healthy pigeons. Twenty eyes of euthanized pigeons were used for the calibration of TonoVet® and 48 eyes of 24 adult pigeons for the reference IOP. First, IOP of pigeon eyes ex vivo were measured using the d and the p modes of the TonoVet® and compared with manometric IOP values from 5
to 80 mmHg. Then, to establish normal reference values, IOP was measured from clinically normal pigeons in vivo. Both the d and the p modes of the TonoVet® showed a strong linear correlation with the manometric IOP (R2 = 0.996 and 0.991, respectively). The obtained regression formulas were y = 0.431x1 + 2.154 and y = 0.330x2 - 0.673, respectively (x1, d mode of TonoVet®
-
dc.description.abstractx2, p mode of TonoVet®-
dc.description.abstracty, manometric IOP). The d and the p modes steadily underestimated the actual IOP by approximately 1/2 and 1/3, respectively. Therefore, the formula obtained through the d mode was applied to obtain reference values. The calibrated IOP of normal pigeon eyes was 19.5 ± 4.4 mmHg. The actual IOP could be calculated using the presented formula. Considering the limitations of the p mode, it would be more appropriate to use the d mode. Therefore, the TonoVet® rebound tonometry under d mode is a reliable method for measuring IOP in pigeons.-
dc.description.tableofcontentsINTRODUCTION 1
MATERIALS AND METHODS 2
1. Experimental animals 2
2. Manomteric calibration of TonoVet® 3
3. Determination of normal pigeon IOP 6
4. Statistical analyses 8
RESULTS 9
1. Manomteric calibration of TonoVet® 9
2. Determination of normal pigeon IOP 13
DISCUSSIONS 15
CONCLUSIONS 18
REFERENCES 19
ABSTRACT IN KOREAN 23
-
dc.formatapplication/pdf-
dc.format.extent969102 bytes-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subjectintraocular pressure-
dc.subjectrebound tonometry-
dc.subjectpigeons-
dc.subjectColumbiformes-
dc.subjectreference values-
dc.subjectlinear regression analysis-
dc.subject.ddc636.089-
dc.titleIntraocular Pressure Measurement with a Rebound Tonometer (TonoVet®) in Normal Pigeons-
dc.typeThesis-
dc.description.degreeMaster-