Publications

Detailed Information

Post-calibration of DTS data and analysis of well completion process monitoring in CO2 geological storage demonstration site : DTS자료의 후교정과 CO2지중저장 관측공 완결과정 모니터링 자료의 분석

DC Field Value Language
dc.contributor.advisor민동주-
dc.contributor.author이다솜-
dc.date.accessioned2018-12-03T01:49:51Z-
dc.date.available2018-12-03T01:49:51Z-
dc.date.issued2018-08-
dc.identifier.other000000152518-
dc.identifier.urihttps://hdl.handle.net/10371/144052-
dc.description학위논문 (석사)-- 서울대학교 대학원 : 공과대학 에너지시스템공학부, 2018. 8. 민동주.-
dc.description.abstractThe DTS temperature profiles obtained during well completion of Koreas first CO2 monitoring well in Janggi, Pohang were analyzed to characterize each well completion process in terms of temperature anomalies and to evaluate the feasibility of DTS as a monitoring tool of well development process. Since DTS temperature, a measure of temperature effect on a scattering of light traveling in fiber, should be calibrated to real temperature and unavoidable depth mismatch during installation should also be corrected, several post calibration methods of depth and temperature are also investigated.



The unavoidable depth mismatch is corrected by applying conventional approach which subtracts the ratio of cable length error to TD (Total Depth) of well from each measurement depth, and confirmed its effectiveness by comparing the result with the location of transition point of steel and FRP (Fiber-Reinforce Plastic) and its effect on temperature change pattern during gas lift.



For temperature correction, several point-wise methods and conventional long-point pre-calibration method are investigated to suggest an effective post-calibration method. The conventional method by submerging a portion of cable longer than the length of resolution cell defined by pulse width or a gauge length of a measurement system in water showed preferable result than the other methods. However, point-wise methods which gave reasonable and comparable results with long-point method also showed that it could be a useful alternative when a long-point method-based pre- & post-calibration cannot be done.



The real-time DTS monitoring data revealed that each well completion processes can be characterized by their own distinctive temperature anomaly patterns. In gravel packing, the progression up the well of the emplaced sand was noticeable as an anomaly and creating a thermal bridge to the warmer formation. The DTS data clearly shows the exothermic reaction associated with curing of cement within the cementing boundary. During gas lift operations, the conventional highly oscillating pattern was observed in the DTS data, but in our case, the casing transition point was delineated. In summary, these imply that real-time DTS monitoring could not only be an effective tool of monitoring but also controlling, and optimization of well completion procedure.
-
dc.description.tableofcontentsChapter 1. Introduction 1

1.1 Background 1

1.2 Research Objectives 3

1.3 Outline 5

Chapter 2. Theory 6

2.1 Basics of fiber optics 6

2.2 Configuration of optical fiber sensors 9

2.3 Principle of scattering 10

2.4 Distributed temperature sensing (DTS) 12

2.5 Temperature decoding 17

2.6 Calibration method 20

2.6.1 Temperature correction 20

2.6.2 Depth correction 22

Chapter 3. Experiment setting with post-calibration method of temperature and depth 24

3.1 Experimental setting 24

3.1.1 Study area 24

3.1.2 Well schematic and completion process 26

3.1.3 Fiber optic installation 30

3.1.4 DTS configuration 32

3.2 Depth correction 33

3.3 Temperature correction 40

3.3.1 Post calibration method 43

3.3.2 Long point calibration method with water tub 46

3.3.3 Point-wise calibration method with heat coil 52

3.3.4 Point-wise calibration method in-well 55

3.3.5 Discussion 58

Chapter 4. Interpretation of Data 61

4.1 Gravel packing 63

4.2 Cement injection and curing process 67

4.3 Gas lift 71

Chapter 5. Conclusion 74

References 76

초 록 79
-
dc.formatapplication/pdf-
dc.format.mediumapplication/pdf-
dc.language.isoen-
dc.publisher서울대학교 대학원-
dc.subject.ddc622.33-
dc.titlePost-calibration of DTS data and analysis of well completion process monitoring in CO2 geological storage demonstration site-
dc.title.alternativeDTS자료의 후교정과 CO2지중저장 관측공 완결과정 모니터링 자료의 분석-
dc.typeThesis-
dc.contributor.AlternativeAuthorDasom Sharon Lee-
dc.description.degreeMaster-
dc.contributor.affiliation공과대학 에너지시스템공학부-
dc.date.awarded2018-08-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share