Publications
Detailed Information
Segmentation of optic nerve head using warping and RANSAC
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Sun Kwon | - |
dc.contributor.author | Kong, Hyoun-Joong | - |
dc.contributor.author | Seo, Jong-Mo | - |
dc.contributor.author | Cho, Bum Joo | - |
dc.contributor.author | Park, Ki Ho | - |
dc.contributor.author | Hwang, Jeong Min | - |
dc.contributor.author | Kim, Dong-Myung | - |
dc.contributor.author | Chung, Hum | - |
dc.contributor.author | Kim, Hee Chan | - |
dc.date.accessioned | 2009-11-26T06:46:32Z | - |
dc.date.available | 2009-11-26T06:46:32Z | - |
dc.date.issued | 2007-11-16 | - |
dc.identifier.citation | Conf Proc IEEE Eng Med Biol Soc. 2007;2007:900-3. | en |
dc.identifier.issn | 1557-170X (Print) | - |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=18002102 | - |
dc.identifier.uri | https://hdl.handle.net/10371/16037 | - |
dc.description.abstract | Glaucoma is the second leading cause of blindness, and the retinal nerve fiber layer (RNFL) defect is the early sign of the glaucomatous optic nerve damage. To evaluate the RNFL, segmentation of the optic nerve head on the RNFL photograph should be the first step. This paper presents segmentation of optic nerve head using warping and random sample consensus (RANSAC). Sensitivity and positive predictability of the proposed method were 91% and 78% respectively. | en |
dc.language.iso | en | - |
dc.subject | Algorithms | en |
dc.subject | Artificial Intelligence | en |
dc.subject | Image Enhancement/*methods | en |
dc.subject | Image Interpretation, Computer-Assisted/*methods | en |
dc.subject | Imaging, Three-Dimensional/*methods | en |
dc.subject | Optic Disk/*anatomy & histology | en |
dc.subject | Pattern Recognition, Automated/*methods | en |
dc.subject | Photography/*methods | en |
dc.subject | Reproducibility of Results | en |
dc.subject | Retinoscopy/*methods | en |
dc.subject | Sensitivity and Specificity | en |
dc.title | Segmentation of optic nerve head using warping and RANSAC | en |
dc.type | Article | en |
dc.contributor.AlternativeAuthor | 김선권 | - |
dc.contributor.AlternativeAuthor | 공현중 | - |
dc.contributor.AlternativeAuthor | 서종모 | - |
dc.contributor.AlternativeAuthor | 조범주 | - |
dc.contributor.AlternativeAuthor | 박기호 | - |
dc.contributor.AlternativeAuthor | 황정민 | - |
dc.contributor.AlternativeAuthor | 김동명 | - |
dc.contributor.AlternativeAuthor | 정흠 | - |
dc.contributor.AlternativeAuthor | 김희찬 | - |
dc.identifier.doi | 10.1109/IEMBS.2007.4352436 | - |
- Appears in Collections:
- Files in This Item:
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.