Publications
Detailed Information
Smartphone / smartwatch-based cuffless blood pressure measurement : a position paper from the Korean Society of Hypertension
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Hae Young | - |
dc.contributor.author | Lee, Dong-Ju | - |
dc.contributor.author | Seo, Jongmo | - |
dc.contributor.author | Ihm, Sang-Hyun | - |
dc.contributor.author | Kim, Kwang-il | - |
dc.contributor.author | Cho, Eun Joo | - |
dc.contributor.author | Kim, Hyeon Chang | - |
dc.contributor.author | Shin, Jinho | - |
dc.contributor.author | Park, Sungha | - |
dc.contributor.author | Sohn, Il-Suk | - |
dc.contributor.author | Chung, Wook-Jin | - |
dc.contributor.author | Ryu, Sung Kee | - |
dc.contributor.author | Sung, Ki Chul | - |
dc.contributor.author | Kim, Juhan | - |
dc.contributor.author | Kim, Dae-Hee | - |
dc.contributor.author | Pyun, Wook Bum | - |
dc.date.accessioned | 2021-03-18T06:12:40Z | - |
dc.date.available | 2021-03-18T15:14:44Z | - |
dc.date.issued | 2021-01-25 | - |
dc.identifier.citation | Clinical Hypertension. 2021 Jan 25;27(1):4 | ko_KR |
dc.identifier.issn | 2056-5909 | - |
dc.identifier.uri | https://hdl.handle.net/10371/173711 | - |
dc.description.abstract | Smartphone technology has spread rapidly around the globe. According to a report released by the Korea Information Society Development Institute, about 95% of Koreans aged more than 30 years old owned smartphones. Recently, blood pressure (BP) measurement using a photoplethysmography-based smartphone algorithm paired with the smartwatch is continuously evolving. In this document, the Korean Society of Hypertension intends to remark the current results of smartphone / smartwatch-based BP measurement and recommend optimal BP measurement methods using a smartphone device. We aim to increase the likelihood of success in implementing these new technologies into improved hypertension awareness, diagnosis, and control. | ko_KR |
dc.language.iso | en | ko_KR |
dc.publisher | BMC | ko_KR |
dc.subject | Blood pressure | - |
dc.subject | Measurement | - |
dc.subject | Hypertension | - |
dc.subject | Smartphone | - |
dc.subject | Plethysmography | - |
dc.title | Smartphone / smartwatch-based cuffless blood pressure measurement : a position paper from the Korean Society of Hypertension | ko_KR |
dc.type | Article | ko_KR |
dc.contributor.AlternativeAuthor | 이해영 | - |
dc.contributor.AlternativeAuthor | 이동주 | - |
dc.contributor.AlternativeAuthor | 서종모 | - |
dc.contributor.AlternativeAuthor | 임상현 | - |
dc.contributor.AlternativeAuthor | 김광일 | - |
dc.contributor.AlternativeAuthor | 조은주 | - |
dc.contributor.AlternativeAuthor | 김현창 | - |
dc.contributor.AlternativeAuthor | 신진호 | - |
dc.contributor.AlternativeAuthor | 박성하 | - |
dc.contributor.AlternativeAuthor | 손일석 | - |
dc.contributor.AlternativeAuthor | 정욱진 | - |
dc.contributor.AlternativeAuthor | 류성기 | - |
dc.contributor.AlternativeAuthor | 성기철 | - |
dc.contributor.AlternativeAuthor | 김주한 | - |
dc.contributor.AlternativeAuthor | 김대희 | - |
dc.contributor.AlternativeAuthor | 편욱범 | - |
dc.identifier.doi | 10.1186/s40885-020-00158-8 | - |
dc.citation.journaltitle | Clinical Hypertension | ko_KR |
dc.language.rfc3066 | en | - |
dc.rights.holder | The Author(s) | - |
dc.date.updated | 2021-01-27T10:45:21Z | - |
dc.citation.number | 1 | ko_KR |
dc.citation.startpage | 4 | ko_KR |
dc.citation.volume | 27 | ko_KR |
- Appears in Collections:
- Files in This Item:
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.