Correlation between two-dimensional micro-CT and histomorphometry for assessment of the implant osseointegration in rabbit tibia model

DC Field Value Language
dc.contributor.authorLyu, Hao-Zhen-
dc.contributor.authorLee, Jae Hyup-
dc.date.accessioned2021-07-09T06:25:37Z-
dc.date.available2021-07-09T15:27:06Z-
dc.date.issued2021-04-13-
dc.identifier.citationBiomaterials Research. 2021 Apr 13;25(1):11ko_KR
dc.identifier.issn2055-7124-
dc.identifier.urihttps://hdl.handle.net/10371/174676-
dc.description.abstractBackground
Histology is considered as a gold standard for analyzing bone architecture. However, histomorphometry is a destructive method and only offers the bone information of a limited location. Micro-computed tomography (μCT) is a non-destructive technology and provides a slice at any site. The aim of this study was to compare the correlation of the Bone-to-Implant Contact ratio (BIC) between 2D micro-CT (μCT) and histomorphometry and to investigate a method for assessing the osseointegration of the implant by 2D μCT.

Methods
A total of 18 implants were divided into three groups (6 implants per group), and inserted into the rabbit tibia defects as follow: implant only (Implant group), implant with β-TCP/hydrogel (TCP group), implant with rhBMP-2 loaded β-TCP/hydrogel composite (BMP-2 group). After 4 weeks of implantation, the specimens were collected to take the micro-CT scan with an aluminum filter and performed H&E staining on the undecalcified sections. The 2D μCT slices were chosen at an angle of 0°, 45°, 90° and 135° with the representative histological section to measure BIC. And the correlations between BICs of 2D μCT and BICs of histology were evaluated.

Results
In each group, BICs at the same sites measured by histomorphometry and corresponding 2D μCT presented the same trend and shown no significant difference between the two methods (P > 0.05). BICs of histological sections and BICs of corresponding 2D μCT slices presented a strong correlation in the implant group (γ = 0.74, P = 0.09), a moderate correlation in the TCP group (γ = 0.46, P = 0.35), a weak correlation in the BMP-2 group (γ = 0.30, P = 0.56). In the implant group, the relationship between BIC-Mean-μCTs and BICs-Histology has presented a significant linear correlation (γ = 0.84, P = 0.04).

Conclusions
Integrating bone information of several 2D μCT slices in different sites to measure BIC is a feasible method for assessing the implant osseointegration.
ko_KR
dc.description.sponsorshipThis work was supported by the Korea Medical Device Development Fund grant funded by the Korea government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety) (Project Number: KMDF_PR_20200901_0151).ko_KR
dc.language.isoenko_KR
dc.publisherBMCko_KR
dc.subjectBone-implant interface-
dc.subjectHistology-
dc.subjectOsseointegration-
dc.subjectX-ray microtomography-
dc.titleCorrelation between two-dimensional micro-CT and histomorphometry for assessment of the implant osseointegration in rabbit tibia modelko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor이재협-
dc.identifier.doi10.1186/s40824-021-00213-x-
dc.citation.journaltitleBiomaterials Researchko_KR
dc.language.rfc3066en-
dc.rights.holderThe Author(s)-
dc.date.updated2021-04-18T03:16:59Z-
dc.citation.number1ko_KR
dc.citation.startpage11ko_KR
dc.citation.volume25ko_KR
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share