Development of an anthropomorphic multimodality pelvic phantom for quantitative evaluation of a deep-learning-based synthetic computed tomography generation technique

Cited 0 time in Web of Science Cited 0 time in Scopus
Authors

Jin, Hyeongmin; Lee, Sung Young; An, Hyun Joon; Choi, Chang Heon; Chie, Eui Kyu; Wu, Hong-Gyun; Park, Jong Min; Park, Sukwon; Kim, Jung-in

Issue Date
2022-08
Publisher
American Institute of Physics
Citation
Journal of applied clinical medical physics [electronic resource] / American College of Medical Physics, Vol.23 No.8, p. e13644
Abstract
Purpose The objective of this study was to fabricate an anthropomorphic multimodality pelvic phantom to evaluate a deep-learning-based synthetic computed tomography (CT) algorithm for magnetic resonance (MR)-only radiotherapy. Methods Polyurethane-based and silicone-based materials with various silicone oil concentrations were scanned using 0.35 T MR and CT scanner to determine the tissue surrogate. Five tissue surrogates were determined by comparing the organ intensity with patient CT and MR images. Patient-specific organ modeling for three-dimensional printing was performed by manually delineating the structures of interest. The phantom was finally fabricated by casting materials for each structure. For the quantitative evaluation, the mean and standard deviations were measured within the regions of interest on the MR, simulation CT (CTsim), and synthetic CT (CTsyn) images. Intensity-modulated radiation therapy plans were generated to assess the impact of different electron density assignments on plan quality using CTsim and CTsyn. The dose calculation accuracy was investigated in terms of gamma analysis and dose-volume histogram parameters. Results For the prostate site, the mean MR intensities for the patient and phantom were 78.1 +/- 13.8 and 86.5 +/- 19.3, respectively. The mean intensity of the synthetic image was 30.9 Hounsfield unit (HU), which was comparable to that of the real CT phantom image. The original and synthetic CT intensities of the fat tissue in the phantom were -105.8 +/- 4.9 HU and -107.8 +/- 7.8 HU, respectively. For the target volume, the difference in D-95% was 0.32 Gy using CTsyn with respect to CTsim values. The V-65Gy values for the bladder in the plans using CTsim and CTsyn were 0.31% and 0.15%, respectively. Conclusion This work demonstrated that the anthropomorphic phantom was physiologically and geometrically similar to the patient organs and was employed to quantitatively evaluate the deep-learning-based synthetic CT algorithm.
ISSN
1526-9914
URI
https://hdl.handle.net/10371/184940
DOI
https://doi.org/10.1002/acm2.13644
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share