Publications

Detailed Information

Cone-beam CT virtual navigation-guided percutaneous needle biopsy of suspicious pleural metastasis: A pilot study

Cited 5 time in Web of Science Cited 5 time in Scopus
Authors

Lim, Hyun-ju; Park, Chang Min; Yoon, Soon Ho; Bae, Jae Seok; Goo, Jin Mo

Issue Date
2018-09
Publisher
대한영상의학회
Citation
Korean Journal of Radiology, Vol.19 No.5, pp.872-879
Abstract
Objective: To evaluate the diagnostic performance of cone-beam computed tomography (CBCT) virtual navigation-guided percutaneous pleural biopsy for suspected malignant pleural disease. Materials and Methods: This study enrolled 59 patients (31 males and 28 females; mean age, 63.4 years) with suspected malignant pleural disease diagnosed with CBCT from December 2010 to December 2016. Sixty-three CBCT-guided biopsies were performed using a coaxial system with 18- or 20-gauge cutting needles. Procedural details, diagnostic performance, radiation exposure, and complication rates were investigated. Results: The mean diameter perpendicular to the pleura of 51 focal and 12 diffuse pleural lesions was 1.53 +/- 0.76 cm. The mean distance from the skin to the target was 3.40 +/- 1.51 cm. Mean numbers of CT acquisitions and biopsies were 3.21 +/- 0.57 and 3.05 +/- 1.54. Total procedure time and coaxial introducer indwelling time were 11.87 +/- 5.59 min and 8.78 +/- 4.95 min, respectively. The mean dose area product was 12013.61 +/- 7969.59 mGym(2). There were 48 malignant, 10 benign, and 5 indeterminate lesions. Sensitivity, specificity, and diagnostic accuracy were 93.8% (45/48), 100% (10/10), and 94.8% (55/58), respectively. Positive and negative predictive values for malignancy were 100% (45/45) and 76.9% (10/13), respectively. Four patients (6.8%) with benign pathology during initial biopsy but still showing a high suspicion of malignancy underwent repeat biopsy and three of them were finally diagnosed with malignant pleural disease. There were three cases of minimal pneumothorax and no grave procedure-related complications. Conclusion: Cone-beam computed tomography-guided biopsy is an accurate and safe diagnostic technique for suspected malignant pleural lesion with reasonable radiation exposure and procedure time.
ISSN
1229-6929
URI
https://hdl.handle.net/10371/206425
DOI
https://doi.org/10.3348/kjr.2018.19.5.872
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area Radiology

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share