Publications

Detailed Information

C- Arm Cone-Beam CT-guided Percutaneous Transthoracic Needle Biopsy of Lung Nodules: Clinical Experience in 1108 Patients

Cited 156 time in Web of Science Cited 171 time in Scopus
Authors

Lee, Sang Min; Park, Chang Min; Lee, Kyung Hee; Bahn, Young Eun; Kim, Jung Im; Goo, Jin Mo

Issue Date
2014-04
Publisher
Radiological Society of North America
Citation
Radiology, Vol.271 No.1, pp.291-300
Abstract
To retrospectively evaluate the diagnostic performance and complications of C-arm cone-beam computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) in 1108 patients. This retrospective study was approved by the institutional review board with waiver of patient informed consent. From January 2009 to December 2011, 1108 patients (633 male, 475 female; mean age, 62.4 years +/- 12.3 [standard deviation]) with 1116 pulmonary lesions (mean size, 2.7 cm +/- 1.7) underwent 1153 cone-beam CT-guided PTNBs. A coaxial system with 18-gauge cutting needles was used. Diagnostic performance, complication rate, influencing factors, and patient radiation exposure were investigated. Variables influencing diagnostic performance and complications were assessed by using uni-and multivariate logistic regression analyses. Among 1153 PTNBs, pathologic analysis showed 1148 (99.6%) were technically successful (766 malignant [66.4%], 323 benign [28.0%], and 59 [5.1%] indeterminate). Sensitivity, specificity, and accuracy for diagnosis of malignancy were 95.7% (733 of 766), 100% (323 of 323), and 97.0% (1056 of 1089), respectively. In regard to diagnostic failures (five technical failures, 33 false-negative findings), lesions 1 cm in diameter or smaller and lesions in the lower lobe were significant risk factors (P = .028 and P = .034, respectively). As for complications, pneumothorax and hemoptysis occurred in 196 (17.0%) and 80 (6.9%) procedures, respectively. Multivariate analysis revealed two or more pleural passages and emphysema along the needle pathway were the two most significant risk factors for pneumothorax, and ground-glass nodules were the most significant risk factor for hemoptysis (P < .001 for all). Virtual guidance was a significant protective factor for both pneumothorax and hemoptysis (P < .001 for both). Mean estimated effective radiation dose through cone-beam CT-guided PTNBs was 7.3 mSv +/- 4.1. Cone-beam CT-guided PTNB is a highly accurate and safe technique with which to diagnose pulmonary lesions with reasonable radiation exposure.
ISSN
0033-8419
URI
https://hdl.handle.net/10371/207455
DOI
https://doi.org/10.1148/radiol.13131265
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area Radiology

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share