Publications

Detailed Information

Diagnostic accuracy of Xpert (R) MTB/RIF on bronchoscopy specimens in patients with suspected pulmonary tuberculosis

DC Field Value Language
dc.contributor.authorLee, H. Y.-
dc.contributor.authorSeong, M. W.-
dc.contributor.authorPark, S. S.-
dc.contributor.authorHwang, S-S.-
dc.contributor.authorLee, J.-
dc.contributor.authorPark, Y. S.-
dc.contributor.authorLee, C. H.-
dc.contributor.authorLee, S-M.-
dc.contributor.authorYoo, C-G.-
dc.contributor.authorKim, Y. W.-
dc.contributor.authorHan, S. K.-
dc.contributor.authorYim, J-J.-
dc.date.accessioned2024-08-08T01:43:31Z-
dc.date.available2024-08-08T01:43:31Z-
dc.date.created2021-04-13-
dc.date.created2021-04-13-
dc.date.issued2013-07-
dc.identifier.citationInternational Journal of Tuberculosis and Lung Disease, Vol.17 No.7, pp.917-921-
dc.identifier.issn1027-3719-
dc.identifier.urihttps://hdl.handle.net/10371/207614-
dc.description.abstractOBJECTIVE: To determine the diagnostic accuracy of the Xpert (R) MTB/RIF assay using samples obtained through bronchoscopy in patients with suspected pulmonary tuberculosis (PTB). DESIGN: We retrospectively reviewed the records of patients with suspected PTB for whom the Xpert MTB/RIF assay was performed on bronchoscopy specimens. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of active PTB were calculated for acid-fast bacilli (AFB) smear microscopy and the Xpert assay using culture of Mycobacterium tuberculosis from sputum or bronchoscopy specimens as a reference standard. RESULTS: A total of 132 patients were included in the final analysis. Of these, 38 had culture-confirmed PTB. The sensitivity of the Xpert assay using bronchial washing or bronchoalveolar lavage (BAL) fluid for the diagnosis of PTB was 81.6%, and specificity was 100%. The PPV and NPV were 100% and 92.1%, respectively. The sensitivity and specificity of AFB smear microscopy were respectively 13.2% and 98.8%. CONCLUSION: The Xpert assay on bronchoscopy specimens provided an accurate diagnosis of PTB in patients who had a negative AFB smear or who could not produce sputum.-
dc.language영어-
dc.publisherInternational Union Against Tuberculosis And Lung Disease/Union Internationale Contre la Tuberculose et les Maladies Respiratories-
dc.titleDiagnostic accuracy of Xpert (R) MTB/RIF on bronchoscopy specimens in patients with suspected pulmonary tuberculosis-
dc.typeArticle-
dc.identifier.doi10.5588/ijtld.12.0885-
dc.citation.journaltitleInternational Journal of Tuberculosis and Lung Disease-
dc.identifier.wosid000320830200011-
dc.identifier.scopusid2-s2.0-84878912021-
dc.citation.endpage921-
dc.citation.number7-
dc.citation.startpage917-
dc.citation.volume17-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorLee, S-M.-
dc.contributor.affiliatedAuthorKim, Y. W.-
dc.contributor.affiliatedAuthorYim, J-J.-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusFIBEROPTIC BRONCHOSCOPY-
dc.subject.keywordPlusSPUTUM SMEAR-
dc.subject.keywordPlusRIFAMPIN RESISTANCE-
dc.subject.keywordPlusBRONCHIAL ASPIRATE-
dc.subject.keywordPlusRAPID DETECTION-
dc.subject.keywordPlusCULTURE-
dc.subject.keywordAuthordiagnosis-
dc.subject.keywordAuthortuberculosis-
dc.subject.keywordAuthorbronchoscopy-
dc.subject.keywordAuthorXpert MTB/RIF assay-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area Nontuberculous Mycobacteria, Tuberculosis, multidrug-resistant tuberculosis, 결핵, 다제내성결핵, 비결핵항산균 폐질환

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share