Publications
Detailed Information
Diagnostic accuracy of Xpert (R) MTB/RIF on bronchoscopy specimens in patients with suspected pulmonary tuberculosis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, H. Y. | - |
dc.contributor.author | Seong, M. W. | - |
dc.contributor.author | Park, S. S. | - |
dc.contributor.author | Hwang, S-S. | - |
dc.contributor.author | Lee, J. | - |
dc.contributor.author | Park, Y. S. | - |
dc.contributor.author | Lee, C. H. | - |
dc.contributor.author | Lee, S-M. | - |
dc.contributor.author | Yoo, C-G. | - |
dc.contributor.author | Kim, Y. W. | - |
dc.contributor.author | Han, S. K. | - |
dc.contributor.author | Yim, J-J. | - |
dc.date.accessioned | 2024-08-08T01:43:31Z | - |
dc.date.available | 2024-08-08T01:43:31Z | - |
dc.date.created | 2021-04-13 | - |
dc.date.created | 2021-04-13 | - |
dc.date.issued | 2013-07 | - |
dc.identifier.citation | International Journal of Tuberculosis and Lung Disease, Vol.17 No.7, pp.917-921 | - |
dc.identifier.issn | 1027-3719 | - |
dc.identifier.uri | https://hdl.handle.net/10371/207614 | - |
dc.description.abstract | OBJECTIVE: To determine the diagnostic accuracy of the Xpert (R) MTB/RIF assay using samples obtained through bronchoscopy in patients with suspected pulmonary tuberculosis (PTB). DESIGN: We retrospectively reviewed the records of patients with suspected PTB for whom the Xpert MTB/RIF assay was performed on bronchoscopy specimens. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of active PTB were calculated for acid-fast bacilli (AFB) smear microscopy and the Xpert assay using culture of Mycobacterium tuberculosis from sputum or bronchoscopy specimens as a reference standard. RESULTS: A total of 132 patients were included in the final analysis. Of these, 38 had culture-confirmed PTB. The sensitivity of the Xpert assay using bronchial washing or bronchoalveolar lavage (BAL) fluid for the diagnosis of PTB was 81.6%, and specificity was 100%. The PPV and NPV were 100% and 92.1%, respectively. The sensitivity and specificity of AFB smear microscopy were respectively 13.2% and 98.8%. CONCLUSION: The Xpert assay on bronchoscopy specimens provided an accurate diagnosis of PTB in patients who had a negative AFB smear or who could not produce sputum. | - |
dc.language | 영어 | - |
dc.publisher | International Union Against Tuberculosis And Lung Disease/Union Internationale Contre la Tuberculose et les Maladies Respiratories | - |
dc.title | Diagnostic accuracy of Xpert (R) MTB/RIF on bronchoscopy specimens in patients with suspected pulmonary tuberculosis | - |
dc.type | Article | - |
dc.identifier.doi | 10.5588/ijtld.12.0885 | - |
dc.citation.journaltitle | International Journal of Tuberculosis and Lung Disease | - |
dc.identifier.wosid | 000320830200011 | - |
dc.identifier.scopusid | 2-s2.0-84878912021 | - |
dc.citation.endpage | 921 | - |
dc.citation.number | 7 | - |
dc.citation.startpage | 917 | - |
dc.citation.volume | 17 | - |
dc.description.isOpenAccess | N | - |
dc.contributor.affiliatedAuthor | Lee, S-M. | - |
dc.contributor.affiliatedAuthor | Kim, Y. W. | - |
dc.contributor.affiliatedAuthor | Yim, J-J. | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.subject.keywordPlus | FIBEROPTIC BRONCHOSCOPY | - |
dc.subject.keywordPlus | SPUTUM SMEAR | - |
dc.subject.keywordPlus | RIFAMPIN RESISTANCE | - |
dc.subject.keywordPlus | BRONCHIAL ASPIRATE | - |
dc.subject.keywordPlus | RAPID DETECTION | - |
dc.subject.keywordPlus | CULTURE | - |
dc.subject.keywordAuthor | diagnosis | - |
dc.subject.keywordAuthor | tuberculosis | - |
dc.subject.keywordAuthor | bronchoscopy | - |
dc.subject.keywordAuthor | Xpert MTB/RIF assay | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.