삼각측량기법을 이용한 광학추적장치의 상악골 변위 계측에 대한 정확성 검증 : Accuracy Verification of Optical Tracking System for the Maxillary Displacement Estimation by Using of Triangulation

Cited 0 time in Web of Science Cited 0 time in Scopus
Authors

경규영; 김성민; 이종호; 명훈; 김명진

Issue Date
2012-01
Publisher
대한악안면성형재건외과학회
Citation
Maxillofacial Plastic and Reconstructive Surgery, Vol.34 No.1, pp.41-52
Abstract
Purpose: Triangulation is the process of determining the location of a point by measuring angles to it from known points at either end of a fixed baseline. This point can be fixed as the third point of a triangle with one known side and two known angles. The aim of this study was to find a clinically adaptable method for applying an optical tracking navigation system to orthognathic surgery and to estimate its accuracy of measuring the bone displacement by use of triangulation methods. Methods: In orthognathic surgery, the head position is not fixed as in neurosurgery, so that a head tracker is needed to establish the reference point on the head surface byusing an optical tracking system. However, the operation field is interfered by its bulkiness that makes its clinical use difficult. To solve this problem, we designed a method using an Aquaplast splinting material and a mini-screw in applying a head tracker on a patient’s forehead. After that, we estimated the accuracy of measuring displacements of the ball marker by an optical tracking system with a conventional head tracker (Group A)and with a newly designed head tracker (Group B). Measured values of ball markers’ displacements by each optical tracking system were compared with values obtained from fusion CT images for an estimation of accuracy. Results: The accuracy of the optical tracking system with a conventional head tracker (Group A) is not suitable for clinical usage. Measured and predictable errors are larger than 10 mm. The optical tracking system with a newly designed head tracker (Group B) shows 1.59 mm, 6.34 mm, and 9.52 mm errorsin threeclinical cases. Conclusion: Most errors were brought on mainly from a lack of reproducibility of the head tracker position. The accuracy of the optical tracking system with a newly designed head tracker can be a useful method in further orthognathic navigation surgery even though the average error is higher than 2.0 mm.
ISSN
2288-8101
URI
https://hdl.handle.net/10371/207905
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • School of Dentistry
  • Department of Dentistry
Research Area Dental implant related bony regeneration, Facial reconstruction, bioactive membrane & E-beam irradiation, 상악동 및 타액선 외과술, 임플란트 골재생술, 턱얼굴 미세수술재건

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share