Publications

Detailed Information

Utility of FDG PET/CT for preoperative staging of non-small cell lung cancers manifesting as subsolid nodules with a solid portion of 3 cm or smaller

Cited 14 time in Web of Science Cited 16 time in Scopus
Authors

Suh, Young Joo; Park, Chang Min; Han, Kyunghwa; Jeon, Sun Kyung; Kim, Hyungjin; Hwang, Eui Jin; Lee, Jong Hyuk; Paeng, Jin Chul; Lee, Chang Hoon; Kim, Young Tae; Goo, Jin Mo

Issue Date
2020-03
Publisher
American Roentgen Ray Society
Citation
American Journal of Roentgenology, Vol.214 No.3, pp.514-523
Abstract
OBJECTIVE. The objective of our study was to investigate the utility of FDG PET/CT for the preoperative staging of subsolid non-small cell lung cancers (NSCLCs) with a solid portion size of 3 cm or smaller. MATERIALS AND METHODS. We retrospectively enrolled 855 patients with pathologically proven NSCLCs manifesting as subsolid nodules with a solid portion of 3 cm or smaller on CT. We then compared the diagnostic performances of FDG PET/CT and chest CT for detecting lymph node (LN), intrathoracic, or distant metastases in patients who underwent preoperative chest CT and FDG PET/CT. After propensity score matching, we compared the diagnostic performance of FDG PET/CT in the group who underwent both chest CT and FDG PET/CT with that of chest CT in patients who did not undergo FDG PET/CT. RESULTS. There were LN metastases in 25 of 765 patients (3.3%) who underwent surgical LN dissection or biopsy and intrathoracic or distant metastasis in two of 855 patients (0.2%). For LN staging, FDG PET/CT showed a sensitivity of 44.0%, specificity of 81.5%, positive predictive value of 9.6%, negative predictive value of 970%, and accuracy of 79.9%, which were lower than those of chest CT for accuracy (p < 0.0001). FDG PET/CT could not accurately detect any intrathoracic or distant metastasis. After propensity score matching, the diagnostic accuracy for LN staging of FDG PET/CT in the group who underwent both CT and FDG PET/CT was lower than that of chest CT in the group who did not undergo FDG PET/CT (p = 0.002), and the diagnostic accuracy for intrathoracic and distant metastases was not different (p> 0.999). CONCLUSION. FDG PET/CT has limited utility in preoperatively detecting LN or distant metastasis in patients with subsolid NSCLCs with a solid portion size of 3 cm or smaller.
ISSN
0361-803X
URI
https://hdl.handle.net/10371/208904
DOI
https://doi.org/10.2214/AJR.19.21811
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area Radiology

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share