Browse
S-Space
College of Dentistry/School of Dentistry (치과대학/치의학대학원)
Dept. of Dentistry (치의학과)
Journal Papers (저널논문_치의학과)
구순구개열 환자의 상악골 열성장에서 골신장술을 위한 Internal distraction device와 Rigid external distraction의 비교 : INTERNAL VS. RIGID EXTERNAL DISTRACTION DEVICE FOR THE MAXILLARY HYPOPLASIA OF CLEFT PATIENTS
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 팽준영 | - |
dc.contributor.author | 명훈 | - |
dc.contributor.author | 황순정 | - |
dc.contributor.author | 서병무 | - |
dc.contributor.author | 최진영 | - |
dc.contributor.author | 이종호 | - |
dc.contributor.author | 정필훈 | - |
dc.contributor.author | 백승학 | - |
dc.contributor.author | 김명진 | - |
dc.date.accessioned | 2010-02-01T09:42:07Z | - |
dc.date.available | 2010-02-01T09:42:07Z | - |
dc.date.issued | 2005 | - |
dc.identifier.citation | 대한악안면성형재건외과학회지 27(4) : 324-333, 2005 | en |
dc.identifier.issn | 1225-4207 | - |
dc.identifier.uri | https://hdl.handle.net/10371/47610 | - |
dc.description.abstract | Distraction osteogenesis for the advancement of hypoplastic maxilla of cleft patients has shown successful results. In this report, rigid external distraction(RED) system and internal distraction device were used for maxillary advancement. Each system has its advantages and disadvantages. Larger amount of advancement can be achieved with RED system. But complex external device may give patients psychological stress. Internal device is invisible. However its distraction amount have limitation for the advancement (< 20mm) and the vector cannot be changed freely during distraction. The authors treated five cleft patients with maxillary hypoplasia(three with RED system and two with internal distractor). Their results were clinically satisfactory. We present the pros and cons of RED and internal system for maxillary distraction osteogenesis. | en |
dc.language.iso | ko | en |
dc.publisher | 대한악안면성형재건외과학회 | en |
dc.subject | Distraction Osteogenesis | en |
dc.subject | Cleft Lip and Palate | en |
dc.subject | Maxillary Hypoplasia | en |
dc.subject | Rigid external distraction | en |
dc.title | 구순구개열 환자의 상악골 열성장에서 골신장술을 위한 Internal distraction device와 Rigid external distraction의 비교 | en |
dc.title.alternative | INTERNAL VS. RIGID EXTERNAL DISTRACTION DEVICE FOR THE MAXILLARY HYPOPLASIA OF CLEFT PATIENTS | en |
dc.type | Article | en |
dc.contributor.AlternativeAuthor | Paeng, Jug-Young | - |
dc.contributor.AlternativeAuthor | Myoung, Hoon | - |
dc.contributor.AlternativeAuthor | Hwang, Soon-Jung | - |
dc.contributor.AlternativeAuthor | Seo, Byoung-Moo | - |
dc.contributor.AlternativeAuthor | Choi, Jin-Young | - |
dc.contributor.AlternativeAuthor | Lee, Jong-Ho | - |
dc.contributor.AlternativeAuthor | Choung, Pill-Hoon | - |
dc.contributor.AlternativeAuthor | Baek, Seung-Hak | - |
dc.contributor.AlternativeAuthor | Kim, Myung-Jin | - |
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.