Publications

Detailed Information

MARGINAL FIT OF THE DIGIDENT CAD/CAM ZIRCONIA CERAMIC CROWNS

DC Field Value Language
dc.contributor.authorKim, Yong-Sun-
dc.contributor.authorYang, Jae-Ho-
dc.date.accessioned2010-02-01T09:56:38Z-
dc.date.available2010-02-01T09:56:38Z-
dc.date.issued2006-
dc.identifier.citation대한치과보철학회지 2006;44(3)en
dc.identifier.issn0301-2875-
dc.identifier.urihttps://hdl.handle.net/10371/47903-
dc.description.abstractStatement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. However most of the statistical inferences are not definite because of sample size, measurement number, measuring instruments, etc, and there have been few studies about the marginal fit of the Digident CAD/ CAM zirconia ceramic crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made by using the Digident CAD / CAM zirconia ceramic crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and Methods. The crowns were made from one extracted maxillary central incisor pre-pared with a 1mm shoulder margin and taper walls by milling machine. The in vitro marginal discrepancies of the digident CAD / CAM zirconia ceramic crowns and control groups(metal ceramic crowns) were evaluated and compared. Twenty crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were for the control (metal-ceramic crowns), for Digident CAD / CAM zirconia ceramic crowns. 2. Marginal gap between Digident CAD / CAM zirconia ceramic crowns and metal ceramic crowns did not show significant difference (P>.05). 3. The Digident CAD/ CAM zirconia ceramic crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.en
dc.language.isoenen
dc.publisher대한치과보철학회en
dc.subjectMarginal fiten
dc.subjectDigident CAD / CAM zirconia ceramic crownen
dc.subjectMetal ceramic crownen
dc.titleMARGINAL FIT OF THE DIGIDENT CAD/CAM ZIRCONIA CERAMIC CROWNSen
dc.typeArticleen
dc.contributor.AlternativeAuthor김용선-
dc.contributor.AlternativeAuthor양재호-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share