Publications

Detailed Information

marginal bone loss around three different implant systems : radiographic evaluation after 1 year

DC Field Value Language
dc.contributor.authorKOAK, J. Y.-
dc.contributor.authorPIAO, C. M.-
dc.contributor.authorLEE, J. E.-
dc.contributor.authorKIM, S. K.-
dc.contributor.authorRHYU, I. C.-
dc.contributor.authorHAN, C. H.-
dc.contributor.authorHERR, Y.-
dc.contributor.authorHEO, S. J.-
dc.date.accessioned2010-04-09T01:02:59Z-
dc.date.available2010-04-09T01:02:59Z-
dc.date.issued2009-08-
dc.identifier.citationJOURNAL OF ORAL REHABILITATION. 2009;36:748-754.en
dc.identifier.issn0305-182X-
dc.identifier.urihttps://hdl.handle.net/10371/62783-
dc.description.abstractSummary This study was designed to radiographically evaluate the effect of surface macro-and microstructures within the coronal portion of the external hex implant at the marginal bone change after loading. The fifty-four patients included in the study were randomly assigned to treatment groups with rough-surface implants (TiUnite, n = 45), a hybrid of smooth and rough surface implants (Restore, n = 45) or rough-surface with microthreads implants (Hexplant, n = 45). Clinical and radiographic examinations were conducted at the time of implant loading (baseline) and at 1-year post-loading. A three-level mixed-effect ancova was used to test the significance of the mean marginal bone change of the three implant groups from baseline to 1-year follow-up. At 1-year, significant differences were noted in marginal bone loss recorded for the three groups (P < 0·0001). The rough surface with microthread implants had a mean crestal bone loss of 0·42 ± 0·27 mm; the rough surface implants, 0·81 ± 0·27 mm; and the hybrid surface implants, 0·89 ± 0·41 mm. Within the limitations of this study, a rough surface with microthreads at the coronal part of implant maintained the marginal bone level against functional loading better than implants without these two features.en
dc.language.isoenen
dc.publisherWiley-Blackwellen
dc.subjectmarginal bone levelen
dc.subjectmicrothreadsen
dc.subjectrough surfaceen
dc.subjectradiographic evaluationen
dc.subjectdental implantsen
dc.titlemarginal bone loss around three different implant systems : radiographic evaluation after 1 yearen
dc.typeArticleen