Publications

Detailed Information

Comparison of the accuracy of the three-dimensional virtual method and the conventional manual method for model surgery and intermediate wafer fabrication

Cited 66 time in Web of Science Cited 66 time in Scopus
Authors

Song, Kyu-Gin; Baek, Seung-Hak

Issue Date
2009-01
Publisher
Elsevier
Citation
Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;107:13-21
Abstract
Objective
The aim was to compare the accuracy of 3-dimensional virtual (3D-VMS) and conventional manual methods (MMS) for model surgery and intermediate wafer (IW) fabrication.

Study design
Twenty-five patients were divided according to presence or absence of anteroposterior movement (groups 1 and 2, respectively) and canting correction (groups 3 and 4, respectively) of the maxilla. After MMS and 3D-VMS, conventional IW and 3D virtual IW (3D-VIW) were fabricated. Additional maxillary casts were mounted on the articulator using these IWs and 3D positions, and the 3D positions were statistically analyzed.

Results
In model surgery, although 3D-VMS was more accurate than MMS, the errors of both methods were less than 1 mm in all groups. In wafer fabrication, vertical change only was significant in groups 1, 2, and 3. Model surgery and wafer fabrication methods did not show significant differences in accuracy.

Conclusion
Three-dimensional VMS was more accurate than MMS. However, the accuracy of 3D-VIW fabrication needs to be improved.
ISSN
1079-2104
Language
English
URI
https://hdl.handle.net/10371/62858
DOI
https://doi.org/10.1016/j.tripleo.2008.06.002