Publications
Detailed Information
Assessing intraocular pressure by rebound tonometer in rats with an air-filled anterior chamber
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Eun Ji | - |
dc.contributor.author | Park, Ki Ho | - |
dc.contributor.author | Kim, Dong Myung | - |
dc.contributor.author | Yoo, Young Cheol | - |
dc.contributor.author | Kang, Shin Hee | - |
dc.contributor.author | Kim, Yu Jeong | - |
dc.date.accessioned | 2010-07-05T01:03:06Z | - |
dc.date.available | 2010-07-05T01:03:06Z | - |
dc.date.issued | 2008-12-18 | - |
dc.identifier.citation | Jpn J Ophthalmol. 2008;52(6):500-503 | en |
dc.identifier.issn | 1613-2246 (Electronic) | - |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=19089574 | - |
dc.identifier.uri | http://www.springerlink.com/content/2387786g12617664/fulltext.pdf | - |
dc.identifier.uri | https://hdl.handle.net/10371/68237 | - |
dc.description.abstract | PURPOSE: To compare rebound tonometer and cannulation as methods for measuring intraocular pressure (IOP) in rats. METHODS: The accuracy of the TonoLab rebound tonometer was determined in eight cannulated rat eyes. IOP was manipulated by changing air pressure from 20 to 100 mmHg at 10-mmHg intervals, and the IOP was measured with the rebound tonometer at each level. The average value of three repeated pressure readings was recorded. Correlation analysis and comparison with the Bland and Altman method were performed. The intraclass correlation coefficient was calculated to assess intraoperator variability. RESULTS: The IOP values measured with the TonoLab rebound tonometer were well correlated with the actual IOP (r (2) = 0.963, P = 0.01). The mean of the difference between the rebound tonometer and actual (cannulation) IOP was 7.41 +/- 7.87%. The intraclass correlation coefficient was 0.9, indicating low intraoperator variability. CONCLUSIONS: The rebound tonometer showed high accuracy and reliability for IOP measurement in rat eyes. | en |
dc.description.sponsorship | This study was supported by an SNUH research
grant 03-2007-012-0. | en |
dc.language.iso | en | en |
dc.publisher | Elsevier | en |
dc.subject | Animals | en |
dc.subject | Catheterization | en |
dc.subject | Linear Models | en |
dc.subject | Male | en |
dc.subject | Rats | en |
dc.subject | Rats, Sprague-Dawley | en |
dc.subject | Reproducibility of Results | en |
dc.subject | Tonometry, Ocular/*instrumentation/*methods/standards | en |
dc.subject | Air | - |
dc.subject | Anterior Chamber | - |
dc.subject | Intraocular Pressure | - |
dc.title | Assessing intraocular pressure by rebound tonometer in rats with an air-filled anterior chamber | en |
dc.type | Article | en |
dc.contributor.AlternativeAuthor | 이은지 | - |
dc.contributor.AlternativeAuthor | 박기호 | - |
dc.contributor.AlternativeAuthor | 김동명 | - |
dc.contributor.AlternativeAuthor | 유영철 | - |
dc.contributor.AlternativeAuthor | 강신희 | - |
dc.contributor.AlternativeAuthor | 김유정 | - |
dc.identifier.doi | 10.1007/s10384-008-0591-1 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.