Publications

Detailed Information

Integration of a nanoporous platinum thin film into a microfluidic system for non-enzymatic electrochemical glucose sensing

DC Field Value Language
dc.contributor.authorJoo, Segyeong-
dc.contributor.authorPark, Sejin-
dc.contributor.authorChung, Taek Dong-
dc.contributor.authorKim, Hee Chan-
dc.date.accessioned2010-07-07T23:30:03Z-
dc.date.available2010-07-07T23:30:03Z-
dc.date.issued2007-03-21-
dc.identifier.citationAnal Sci. 2007, 23(3):277-281en
dc.identifier.issn0910-6340 (Print)-
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=17372368-
dc.identifier.urihttps://hdl.handle.net/10371/68470-
dc.description.abstractIn this paper, we describe an amperometric-type enzymeless glucose sensing system based on a nanoporous platinum (Pt) electrode embedded in a microfluidic chip. This microchip system is comprised of a microfluidic transport channel network and a miniaturized electrochemical cell for nonenzymatic glucose sensing. Sample and buffer solutions were transferred to the cell by programmed electroosmotic flow (EOF). A nanoporous Pt electrode with the roughness factor of 200.6 was utilized to determine glucose concentrations in phosphate buffered saline (PBS) by the direct oxidation of glucose, without any separation process. The sensitivity of the developed system is 1.65 microA cm-2 mM-1 in the glucose concentration range from 1-10 mM in PBS.en
dc.description.sponsorshipThis work was supported by the Korea Science and Engineering
Foundation through the Advanced Biometric Research Center
(HCK) and by the grant No. R01-2006-000-10240-0 from the
Basic Research Program of the Korea Science & Engineering
Foundation (TDC).
en
dc.language.isoenen
dc.publisherThe Japan Society of Analytical Chemistry / The Japan Society for Analytical Chemistryen
dc.subjectElectrochemistryen
dc.subjectEnzymesen
dc.subjectGlucose/*analysisen
dc.subjectMicrofluidic Analytical Techniques/*instrumentationen
dc.subjectNanotechnology/*instrumentationen
dc.subjectPlatinum/*chemistryen
dc.subjectPorosityen
dc.titleIntegration of a nanoporous platinum thin film into a microfluidic system for non-enzymatic electrochemical glucose sensingen
dc.typeArticleen
dc.contributor.AlternativeAuthor주세경-
dc.contributor.AlternativeAuthor박세진-
dc.contributor.AlternativeAuthor정택동-
dc.contributor.AlternativeAuthor김희찬-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share