Detection of ABH blood group antigens in the saliva of Koreans and their stability according to storage of saliva samples
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, W. | - |
dc.contributor.author | Kim, Y. K. | - |
dc.contributor.author | Chung, S. C. | - |
dc.contributor.author | Lee, S. W. | - |
dc.contributor.author | Kho, H. S. | - |
dc.date.accessioned | 2010-08-03T23:56:30Z | - |
dc.date.available | 2010-08-03T23:56:30Z | - |
dc.date.issued | 2002-09 | - |
dc.identifier.citation | Forensic Science International 129 (2002) 58-63 | en |
dc.identifier.issn | 0379-0738 | - |
dc.identifier.uri | https://hdl.handle.net/10371/68912 | - |
dc.description.abstract | The purpose of the present study was to identify salivary molecules carrying the ABH blood group antigens in Koreans and to investigate the changes in these antigens according to processing and storage of saliva samples. Secretor or non-secretor phenotypes and salivary components carrying the ABH antigens were identified in 90 subjects, 30 subjects in each ABO blood group, by SDS-PAGE and immunoblotting. Saliva samples were then obtained from 12 secretors—two males and two females in each ABO blood group and aliquots of both fresh saliva samples and their supernatants after centrifugation were stored at room temperature, 4, −20 and −70 °C. The same experiments were performed after 1, 3 and 6 months to investigate changes in the blood group antigens. In all 68 secretors, high-molecular-weight salivary mucin (MG1) was found to be the primary carrier of the ABH antigens. A salivary component of approximately 80 kDa also carried H antigen in seven saliva samples of 22 blood type O secretors. The blood group antigens were better detected in centrifuged samples. In saliva samples preserved at room temperature and 4 °C, the blood group antigens were either not detected or detected as degraded molecules. No change was found in the blood group antigens in saliva samples preserved at −20 and −70 °C for 6 months. | en |
dc.description.sponsorship | This study was supported by a grant from the Korea Health 21 R&D Project, Ministry of Health & Welfare, Republic of Korea, HMP-00-CH-10-0009. | en |
dc.language.iso | en | en |
dc.publisher | Elsevier | en |
dc.subject | Saliva | en |
dc.subject | Blood group antigens | en |
dc.subject | Mucin | en |
dc.title | Detection of ABH blood group antigens in the saliva of Koreans and their stability according to storage of saliva samples | en |
dc.type | Article | en |
dc.identifier.doi | 10.1016/S0379-0738(02)00223-2 | - |