The effect of consistency, specimen geometry and adhesion on the axial polymerization shrinkage measurement of light cured composites

DC Field Value Language
dc.contributor.authorSon, Ho-Hyun-
dc.contributor.authorLee, In-Bog-
dc.contributor.authorCho, Byeong-Hoon-
dc.contributor.authorUm, Chung-Moon-
dc.contributor.authorLim, Bum-Soon-
dc.date.accessioned2010-09-03T04:48:19Z-
dc.date.available2010-09-03T04:48:19Z-
dc.date.issued2006-11-
dc.identifier.citationDENTAL MATERIALS 2006;22:1071-1079en
dc.identifier.issn0109-5641-
dc.identifier.urihttps://hdl.handle.net/10371/69647-
dc.description.abstractObjectives
This study investigated the effect of the consistency, specimen geometry and adhesion on the measurements of axial polymerization shrinkage of light cured composite resins using an axial shrinkage-measuring device.

Methods
Four commercially available composites were examined: an anterior posterior hybrid composite Z100, a posterior packable composite P60 and two flowable composites, Filtek flow and Tetric flow. The axial polymerization shrinkage of the composites was determined using a bonded disc method and non-bonded free shrinkage method at varying C-factors by altering the specimen geometry. These measured axial shrinkages were compared with the free volumetric shrinkages. The consistency of the composites was also compared using a squeeze test.

Results
Using the non-bonded method, the axial shrinkage was approximately one third of the true volumetric shrinkage as a result of isotropic contraction. However, in the bonded disc method, the axial shrinkage increased up to the volumetric shrinkage by anisotropic contraction as the bonded surface increased. The axial shrinkage increased with the increasing C-factor. It approached the true volumetric shrinkage and reached a plateau at near a C-factor of 5–6. However, in flowable composites, a lower level of axial shrinkage was measured by the compensational radial flow.

Significance
When estimating the volumetric shrinkage from the axial shrinkage measured using the bonded disc method, the C-factor of the specimen should be higher than 5 and the consistency of the composite is also an important factor that needs to be considered.
en
dc.description.sponsorshipThis study was supported in part by a grant (no. 03-PJ1-PG1-
CH09-0001) from the Ministry of Health andWelfare, Republic
of Korea.
en
dc.language.isoenen
dc.publisherElsevieren
dc.subjectAnisotropyen
dc.subjectPolymerization shrinkageen
dc.subjectBonded disc methoden
dc.subjectFlowen
dc.subjectConsistencyen
dc.subjectC-factoren
dc.subjectLight cured compositesen
dc.titleThe effect of consistency, specimen geometry and adhesion on the axial polymerization shrinkage measurement of light cured compositesen
dc.typeArticleen
dc.contributor.AlternativeAuthor손호현-
dc.contributor.AlternativeAuthor이인복-
dc.contributor.AlternativeAuthor조병훈-
dc.contributor.AlternativeAuthor엄정문-
dc.contributor.AlternativeAuthor임범순-
dc.identifier.doi10.1016/j.dental.2005.08.012-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share