Publications

Detailed Information

Characterization and in vivo evaluation of calcium phosphate coated cp-titanium by dip-spin method

DC Field Value Language
dc.contributor.authorYeo, In-Sung-
dc.contributor.authorYou, Changkook-
dc.contributor.authorKim, Myung-Duk-
dc.contributor.authorEom, Tae-Kwan-
dc.contributor.authorLee, Jae-Yeol-
dc.contributor.authorKim, Sukyoung-
dc.date.accessioned2010-12-28T09:57:01Z-
dc.date.available2010-12-28T09:57:01Z-
dc.date.issued2005-12-
dc.identifier.citationCurrent Applied Physics 5 (2005) 501-506en
dc.identifier.issn1567-1739-
dc.identifier.urihttps://hdl.handle.net/10371/72046-
dc.description.abstractCalcium phosphate ceramics like hydroxyapatite (HA) and tricalcium phosphate (TCP) are good candidates for bone substitutes due to their chemical similarity to bone minerals. Additionally, the biodegradation property of bone substitutes may allow the organism to replace the foreign material by fully functional new bone in a balanced time schedule. Thus, the coating of biodegradable calcium phosphate ceramics on dental implants was conducted in this study to enhance the biocompatibility and eliminate the long-term adverse effects of HA coated implants. First, biodegradable calcium metaphosphate(CMP) sol was prepared and then coated on cp-Ti substrates by a dip-spin coating technique. The coated specimens were heat-treated at 600 for 6 h. CMP coated layer on cp-Ti was smooth and uniform with fine grains. It is observed that bone-to-implant contact area of CMP coated specimen at both 2 and 6 weeks was significantly higher than that of non-coated group. The biocompatibility and cytotoxicity of the CMP coated specimen were better than those of the non-coated specimen. Therefore, the CMP coating on cp-Ti is a good candidate for improving bone-to-implant osseointegration, although it is difficult to extrapolate in vitro results directly to in vivo situation.en
dc.language.isoenen
dc.publisherElsevieren
dc.subjectCalcium metaphosphateen
dc.subjectSol–gelen
dc.subjectCoatingen
dc.subjectDegradationen
dc.subjectBiocompatibilityen
dc.subjectOsseointegrationen
dc.titleCharacterization and in vivo evaluation of calcium phosphate coated cp-titanium by dip-spin methoden
dc.typeArticleen
dc.contributor.AlternativeAuthor여인성-
dc.contributor.AlternativeAuthor유창국-
dc.contributor.AlternativeAuthor김명덕-
dc.contributor.AlternativeAuthor이재열-
dc.contributor.AlternativeAuthor김석영-
dc.identifier.doi10.1016/j.cap.2005.01.020-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share