Browse

Rotational Stability of a Single-Piece Hydrophobic Acrylic Intraocular Lens During Removal of Ophthalmic Viscosurgical Devices

DC Field Value Language
dc.contributor.authorHyon, Joon Young-
dc.contributor.authorYeo, Hwan Eok-
dc.date.accessioned2012-06-29T04:25:59Z-
dc.date.available2012-06-29T04:25:59Z-
dc.date.issued2010-02-
dc.identifier.citationAMERICAN JOURNAL OF OPHTHALMOLOGY; Vol.149 2; 253-257ko_KR
dc.identifier.issn0002-9394-
dc.identifier.urihttps://hdl.handle.net/10371/77907-
dc.description.abstractPURPOSE: To compare the effect of cohesive and dispersive ophthalmic viscosurgical device (OVD) on intraoperative rotational stability of the intraocular lens (IOL) with single-piece hydrophobic acrylate platform. DESIGN: Prospective, comparative study. METHODS: This institutional clinical study included 60 eyes of 60 patients who underwent phacoemulsifcation. The patients were equally divided into cohesive OVD (Healon GV; Abbott Medical Optics, Abbott Park, Illinois, USA) group and dispersive OVD (Viscoat; Alcon Laboratories, Fort Worth, Texas, USA) group. Image analysis from the captured digital image was used to measure intraoperative rotation of single-piece hydrophobic acrylate IOL (SA60AT or SA60NT) during OVD removal. RESULTS: Mean intraoperative rotation was 7.42 degrees +/- 4.16 (standard deviation) in dispersive OVD group and 13.08 degrees +/- 5.25 (standard deviation) in cohesive OVD group (P < .001). Twenty-one cases (70%) maintained the alignment within 10 degrees during removal of OVD with dispersive OVD, while only 9 cases (30%) did so with cohesive OVD (P = .005). Counterclockwise rotation was observed in 33% of the all cases. CONCLUSIONS: This study showed that a significant amount of IOL rotation occurred during OVD removal. Intraoperative rotational stability of IOL was greater with Viscoat than with Healon GV. (Am J Ophthalmol 2010; 149:253-257. (C) 2010 by Elsevier Inc. All rights reserved.)ko_KR
dc.language.isoenko_KR
dc.publisherELSEVIER SCIENCE INCko_KR
dc.titleRotational Stability of a Single-Piece Hydrophobic Acrylic Intraocular Lens During Removal of Ophthalmic Viscosurgical Devicesko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor현준영-
dc.contributor.AlternativeAuthor여환억-
dc.identifier.doi10.1016/j.ajo.2009.08.014-
dc.citation.journaltitleAMERICAN JOURNAL OF OPHTHALMOLOGY-
dc.description.citedreferenceChang DF, 2008, J CATARACT REFR SURG, V34, P1842, DOI 10.1016/j.jcrs.2008.07.012-
dc.description.citedreferenceJampaulo M, 2008, AM J OPHTHALMOL, V146, P550, DOI 10.1016/j.ajo.2008.05.040-
dc.description.citedreferenceMendicute J, 2008, J CATARACT REFR SURG, V34, P601, DOI 10.1016/j.jcrs.2007.11.033-
dc.description.citedreferenceKhng C, 2008, J CATARACT REFR SURG, V34, P475, DOI 10.1016/j.jcrs.2007.10.043-
dc.description.citedreferenceLee AC, 2008, CURR OPIN OPHTHALMOL, V19, P13-
dc.description.citedreferenceWeinand F, 2007, J CATARACT REFR SURG, V33, P800, DOI 10.1016/j.jcrs.2007.01.030-
dc.description.citedreferenceStorr-Paulsen A, 2007, ACTA OPHTHALMOL SCAN, V85, P183, DOI 10.1111/j.1600-0420.2006.00784.x-
dc.description.citedreferenceHorn JD, 2007, CURR OPIN OPHTHALMOL, V18, P58-
dc.description.citedreferenceDe Silva DJ, 2006, J CATARACT REFR SURG, V32, P1492, DOI 10.1016/j.jcrs.2006.04.022-
dc.description.citedreferenceNICHAMIN LD, 2006, OPHTHALMOL CLIN N AM, V19, P485-
dc.description.citedreferenceViestenz A, 2005, J CATARACT REFR SURG, V31, P557, DOI 10.1016/j.jcrs.2004.07.019-
dc.description.citedreferenceChang DF, 2003, J CATARACT REFR SURG, V29, P935, DOI 10.1016/S0886-3350(02)01843-6-
dc.description.citedreferenceTill JS, 2002, J CATARACT REFR SURG, V28, P295-
dc.description.citedreferenceLeyland M, 2001, EYE, V15, P202-
dc.description.citedreferenceDONG EY, 2001, KOREAN J OPHTHALMOL, V15, P22-
dc.description.citedreferenceSun XY, 2000, OPHTHALMOLOGY, V107, P1776-
dc.description.citedreferenceRuhswurm I, 2000, J CATARACT REFR SURG, V26, P1022-
dc.description.citedreferenceRaviv T, 2000, INT OPHTHALMOL CLIN, V40, P183-
dc.description.citedreferenceNOVIS C, 2000, CURR OPIN OPHTHALMOL, V11, P47-
dc.description.citedreferencePatel CK, 1999, OPHTHALMOLOGY, V106, P2190-
dc.description.citedreferenceJacobs BJ, 1999, J CATARACT REFR SURG, V25, P949-
dc.description.citedreferenceGRABOW HB, 1999, CLEAR CORNEAL LENS S, P185-
dc.description.citedreferenceBudak K, 1998, J CATARACT REFR SURG, V24, P503-
dc.description.citedreferenceARSHINOFF SA, 1997, P 7 ANN NAT OPHTH SP, P29-
dc.description.citedreferenceKOHNEN T, 1995, J CATARACT REFR SURG, V21, P417-
dc.description.citedreferenceKERSHNER RM, 1995, J CATARACT REFR SURG, V21, P274-
dc.description.citedreferenceLANGERMAN DW, 1994, J CATARACT REFR SURG, V20, P84-
dc.description.citedreferenceLINDSTROM RL, 1994, CURR OPIN OPHTHALMOL, V5, P1-
dc.description.citedreferenceMALONEY WF, 1992, J CATARACT REFR SURG, V18, P190-
dc.description.citedreferenceLIESEGANG TJ, 1990, SURV OPHTHALMOL, V34, P268-
dc.description.citedreferenceHOFFER KJ, 1980, AM J OPHTHALMOL, V90, P360-
dc.description.tc2-
Appears in Collections:
College of Medicine/School of Medicine (의과대학/대학원)Ophthalmology (안과학전공)Journal Papers (저널논문_안과학전공)
Files in This Item:
There are no files associated with this item.
  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse