Publications

Detailed Information

Comparison of two- and three-dimensional camera systems in laparoscopic performance: a novel 3D system with one camera

DC Field Value Language
dc.contributor.authorKong, Seong-Ho-
dc.contributor.authorOh, Byung-Mo-
dc.contributor.authorYoon, Hongman-
dc.contributor.authorAhn, Hye Seong-
dc.contributor.authorChung, Sun Geun-
dc.contributor.authorKitano, Seigo-
dc.contributor.authorYang, Han-Kwang-
dc.contributor.authorShiraishi, Norio-
dc.contributor.authorLee, Hyuk-Joon-
dc.date.accessioned2012-06-29T08:31:54Z-
dc.date.available2012-06-29T08:31:54Z-
dc.date.issued2010-05-
dc.identifier.citationSURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES; Vol.24 5; 1132-1143ko_KR
dc.identifier.issn0930-2794-
dc.identifier.urihttps://hdl.handle.net/10371/77989-
dc.description.abstractThis study evaluated the effects of a three-dimensional (3D) imaging system on laparoscopy performance compared with the conventional 2D system using a novel one-camera 3D system. In this study, 21 novices and 6 experienced surgeons performed two tasks with 2D and 3D systems in 4 consecutive days. Performance time and error as well as subjective parameters such as depth perception and visual discomforts were assessed in each session. Electromyography was used to evaluate the usage of muscles. The 3D system provided significantly greater depth perception than the 2D system. The errors during the two tasks were significantly lower with 3D system in novice group, but performance time was not different between the 2D and 3D systems. The novices had more dizziness with the 3D system in first 2 days. However, the severity of dizziness was minimal (less than 2 of 10) and overcome with the passage of time. About 54% of the novices and 80% of the experienced surgeons preferred the 3D system. Electromyography (EMG) showed a tendency toward less usage of the right arm and more usage of the left arm with the 3D system. The new 3D imaging system increased the accuracy of laparoscopy performance, with greater depth perception and only minimal dizziness. The authors expect that the 3D laparoscopic system could provide good depth perception and accuracy in surgery.ko_KR
dc.language.isoenko_KR
dc.publisherSPRINGERko_KR
dc.subjectImaging and virtual realityko_KR
dc.subjectSurgicalko_KR
dc.subjectTrainingko_KR
dc.titleComparison of two- and three-dimensional camera systems in laparoscopic performance: a novel 3D system with one camerako_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor공성호-
dc.contributor.AlternativeAuthor오병모-
dc.contributor.AlternativeAuthor윤홍만-
dc.contributor.AlternativeAuthor안혜성-
dc.contributor.AlternativeAuthor이혁준-
dc.contributor.AlternativeAuthor정선근-
dc.contributor.AlternativeAuthor양한광-
dc.identifier.doi10.1007/s00464-009-0740-8-
dc.citation.journaltitleSURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES-
dc.description.citedreferenceFishman JM, 2008, SURG ENDOSC, V22, P2396, DOI 10.1007/s00464-008-0032-8-
dc.description.citedreferenceGofrit ON, 2008, UROLOGY, V71, P404, DOI 10.1016/j.urology.2007.07.077-
dc.description.citedreferenceVotanopoulos K, 2008, WORLD J SURG, V32, P110, DOI 10.1007/s00268-007-9253-6-
dc.description.citedreferenceVlaovic PD, 2008, JSLS-J SOC LAPAROEND, V12, P1-
dc.description.citedreferenceHagiike M, 2007, SURG ENDOSC, V21, P1849, DOI 10.1007/s00464-007-9541-0-
dc.description.citedreferencePatel HRH, 2007, UROLOGY, V70, P47, DOI 10.1016/j.urology.2007.03.014-
dc.description.citedreferenceByrn JC, 2007, AM J SURG, V193, P519, DOI 10.1016/j.amjsurg.2006.06.042-
dc.description.citedreferenceGuru KA, 2007, J AM COLL SURGEONS, V204, P96, DOI 10.1016/j.jamcollsurg.2006.09.016-
dc.description.citedreferenceGalleano R, 2006, ANN SURG, V243, P329, DOI 10.1097/01.sla.0000201481.08336.dc-
dc.description.citedreferenceBlehm C, 2005, SURV OPHTHALMOL, V50, P253, DOI 10.1016/j.survophthal.2005.02.008-
dc.description.citedreferenceJourdan IC, 2004, BRIT J SURG, V91, P879, DOI 10.1002/bjs.4549-
dc.description.citedreferenceGallagher AG, 2003, SURG ENDOSC, V17, P1468, DOI 10.1007/s00464-002-8569-4-
dc.description.citedreferenceYohannes P, 2002, UROLOGY, V60, P39-
dc.description.citedreferenceBerguer R, 2001, SURG ENDOSC-ULTRAS, V15, P1204-
dc.description.citedreferenceTevaearai HT, 2000, ENDOSCOPY, V32, P464-
dc.description.citedreferenceHanna GB, 2000, WORLD J SURG, V24, P444-
dc.description.citedreferenceSun CC, 2000, UROL INT, V64, P154-
dc.description.citedreferenceHANNA GB, 2000, WORLD J SURG, V24, P448-
dc.description.citedreferenceBerguer R, 1999, ERGONOMICS, V42, P1634-
dc.description.citedreferenceTaffinder N, 1999, SURG ENDOSC-ULTRAS, V13, P1087-
dc.description.citedreferenceHerron DM, 1999, SURG ENDOSC, V13, P751-
dc.description.citedreferenceMueller MD, 1999, SURG ENDOSC-ULTRAS, V13, P469-
dc.description.citedreferencevan Bergen P, 1998, SURG ENDOSC-ULTRAS, V12, P948-
dc.description.citedreferenceHanna GB, 1998, LANCET, V351, P248-
dc.description.citedreferenceChan ACW, 1997, SURG ENDOSC-ULTRAS, V11, P438-
dc.description.citedreferenceTENDICK F, 1997, COMPUT AIDED SURG, V2, P24-
dc.description.citedreferencePeitgen K, 1996, GASTROINTEST ENDOSC, V44, P262-
dc.description.citedreferenceMcDougall EM, 1996, J ENDOUROL, V10, P371-
dc.description.citedreferenceVoorhorst FA, 1996, MED PROG TECHNOL, V21, P211-
dc.description.citedreferenceBIRKETT DH, 1994, SURG ENDOSC-ULTRAS, V8, P1448-
dc.description.citedreferencePEROTTO AO, 1994, ANATOMICAL GUIDE ELE-
dc.description.citedreferenceBECKER H, 1993, ENDOSC SURG ALLIED T, V1, P40-
dc.description.tc0-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share