Detection and characterization of focal hepatic lesions by T(2)-weighted imaging: comparison of navigator-triggered turbo spin-echo, breath-hold turbo spin-echo, and HASTE sequences

Cited 2 time in Web of Science Cited 2 time in Scopus
Authors

Lee, Ho Yun; Lee, Jeong Min; Kim, Se Hyung; Shin, Kyung Sook; Han, Joon Koo; Choi, Byung Ihn; Lee, Jae Young

Issue Date
2009-08
Publisher
ELSEVIER SCIENCE INC
Citation
CLINICAL IMAGING; Vol.33 4; 281-288
Keywords
LiverPulse sequencesNeoplasmsMagnetic resonance (MR)Comparative studies
Abstract
The aim of this study is to evaluate the diagnostic performance of T(2)-weighted (T(2)-w) images obtained using navigator-triggered turbo spin-echo (TSE), breath-hold TSE (BH-TSE), and BH haft-Fourier single-shot TSE sequences for the detection and characterization of focal hepatic lesions. Two blinded reviewers independently analyzed three types of T(2)-w image sets totaling 86 solid and 75 nonsolid lesions in 59 patients. Receiver operating characteristic curves were established to analyze reviewer and sequence results. Crown Copyright (C) 2009 Published by Elsevier Inc. All rights reserved.