Publications

Detailed Information

Cortical bone thickness and root proximity at mandibular interradicular sites: implications for orthodontic mini-implant placement : 하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구

DC Field Value Language
dc.contributor.authorLim, Ju-Eun-
dc.contributor.authorLim, Won-Hee-
dc.contributor.authorChun, Youn-Sic-
dc.date.accessioned2013-01-14T07:13:32Z-
dc.date.available2013-01-14T07:13:32Z-
dc.date.issued2008-12-
dc.identifier.citationKOREAN JOURNAL OF ORTHODONTICS, Vol.38, No.6, pp.397-406ko_KR
dc.identifier.issn1225-5610-
dc.identifier.urihttps://hdl.handle.net/10371/80453-
dc.description.abstractObjective: The purpose of this study was to provide clinical guidelines to indicate the best location for mini-implants as it relates to the cortical bone thickness and root proximity. Methods: CT images from 14 men and 14 women were used to evaluate the buccal interradicular cortical bone thickness and root proximity from mesial to the central incisor to the 2nd molar. Cortical bone thickness was measured at 4 different angles including 0 degrees, 15 degrees, 30 degrees, and 45 degrees. Results: There was a statistically significant difference in cortical bone thickness between the second premolar/first permanent molar site, central incisor/central incisor site, between the first/second permanent molar site and in the anterior region. A statistically significant difference in cortical bone thickness was also found when the angulation of placement was increased except for the 2 mm level from the alveolar crest. Interradicular spaces at the 1st/2nd premolar, 2nd premolar/1st permanent molar and 1st/2nd permanent molar sites are considered to be wide enough for mini-implant placement without root damage. Conclusions: Given the limits of this study, mini-implants for orthodontic anchorage may be well placed at the 4 and 6 mm level from the alveolar crest in the posterior region with a 30 degrees and 45 degrees angulation upon placement. (Korean J Orthod 2008; 38(6):397-406)ko_KR
dc.language.isokoko_KR
dc.publisherKOREAN ASSOC ORTHODONTISTSko_KR
dc.subjectMini-implantko_KR
dc.subjectCortical bone thicknessko_KR
dc.subjectRoot proximityko_KR
dc.titleCortical bone thickness and root proximity at mandibular interradicular sites: implications for orthodontic mini-implant placementko_KR
dc.title.alternative하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구ko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor임주은-
dc.contributor.AlternativeAuthor임원희-
dc.contributor.AlternativeAuthor전윤식-
dc.identifier.doi10.4041/kjod.2008.38.6.397-
dc.citation.journaltitleKOREAN JOURNAL OF ORTHODONTICS-
dc.description.tc4-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share