Publications
Detailed Information
Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Song, Tae-Jin | - |
dc.contributor.author | Kwon, Taek-Ka | - |
dc.contributor.author | Yang, Jae-Ho | - |
dc.contributor.author | Han, Jung-Suk | - |
dc.contributor.author | Lee, Jai-Bong | - |
dc.contributor.author | Kim, Sung-Hun | - |
dc.contributor.author | Yeo, In-Sung | - |
dc.creator | 여인성 | - |
dc.date.accessioned | 2013-10-23T04:45:26Z | - |
dc.date.available | 2013-10-23T04:45:26Z | - |
dc.date.issued | 2013-08 | - |
dc.identifier.citation | Journal of Advanced Prosthodontics Vol.5 No.3, pp. 219-225 | - |
dc.identifier.issn | 2005-7806 (print) | - |
dc.identifier.issn | 2005-7814 (online) | - |
dc.identifier.uri | https://hdl.handle.net/10371/83762 | - |
dc.description.abstract | PURPOSE : Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metalceramic FPDs.
MATERIALS AND METHODS : Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs.They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using oneway ANOVA and Duncan test. RESULTS : Mean marginal gaps of 3-unit FPDs were 60.46 μm for the Everest group, 78.71 μm for the Lava group, and 81.32 μm for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05). CONCLUSION : The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration. | en |
dc.language.iso | ko | en |
dc.publisher | The Korean Academy of Prosthodontics | en |
dc.subject | 의약학 | en |
dc.subject | Marginal fit | - |
dc.subject | CAD/CAM | - |
dc.subject | Zirconia FPD | - |
dc.title | Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems | en |
dc.type | Article | - |
dc.author.alternative | 송태진 | - |
dc.author.alternative | 권택가 | - |
dc.author.alternative | 양재호 | - |
dc.author.alternative | 한중석 | - |
dc.author.alternative | 이재봉 | - |
dc.author.alternative | 김성훈 | - |
dc.author.alternative | 여인성 | - |
dc.identifier.doi | 10.4047/jap.2013.5.3.219 | - |
dc.citation.journaltitle | Journal of Advanced Prosthodontics | - |
dc.description.srnd | OAIID:oai:osos.snu.ac.kr:snu2013-01/102/2008003883/10 | - |
dc.description.srnd | SEQ:10 | - |
dc.description.srnd | PERF_CD:SNU2013-01 | - |
dc.description.srnd | EVAL_ITEM_CD:102 | - |
dc.description.srnd | USER_ID:2008003883 | - |
dc.description.srnd | ADJUST_YN:N | - |
dc.description.srnd | EMP_ID:A078517 | - |
dc.description.srnd | DEPT_CD:861 | - |
dc.description.srnd | CITE_RATE:0 | - |
dc.description.srnd | FILENAME:첨부된 내역이 없습니다. | - |
dc.description.srnd | DEPT_NM:치의학과 | - |
dc.description.srnd | EMAIL:pros53@snu.ac.kr | - |
dc.description.srnd | SCOPUS_YN:N | - |
dc.description.srnd | CONFIRM:Y | - |
dc.identifier.srnd | 2013-01/102/2008003883/10 | - |
- Appears in Collections:
- Files in This Item:
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.