Publications

Detailed Information

Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

DC Field Value Language
dc.contributor.authorSong, Tae-Jin-
dc.contributor.authorKwon, Taek-Ka-
dc.contributor.authorYang, Jae-Ho-
dc.contributor.authorHan, Jung-Suk-
dc.contributor.authorLee, Jai-Bong-
dc.contributor.authorKim, Sung-Hun-
dc.contributor.authorYeo, In-Sung-
dc.creator여인성-
dc.date.accessioned2013-10-23T04:45:26Z-
dc.date.available2013-10-23T04:45:26Z-
dc.date.issued2013-08-
dc.identifier.citationJournal of Advanced Prosthodontics Vol.5 No.3, pp. 219-225-
dc.identifier.issn2005-7806 (print)-
dc.identifier.issn2005-7814 (online)-
dc.identifier.urihttps://hdl.handle.net/10371/83762-
dc.description.abstractPURPOSE : Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metalceramic FPDs.
MATERIALS AND METHODS : Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs.They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using oneway ANOVA and Duncan test. RESULTS : Mean marginal gaps of 3-unit FPDs were 60.46 μm for the Everest group, 78.71 μm for the Lava group, and 81.32 μm for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05).
CONCLUSION : The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.
en
dc.language.isokoen
dc.publisherThe Korean Academy of Prosthodonticsen
dc.subject의약학en
dc.subjectMarginal fit-
dc.subjectCAD/CAM-
dc.subjectZirconia FPD-
dc.titleMarginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systemsen
dc.typeArticle-
dc.author.alternative송태진-
dc.author.alternative권택가-
dc.author.alternative양재호-
dc.author.alternative한중석-
dc.author.alternative이재봉-
dc.author.alternative김성훈-
dc.author.alternative여인성-
dc.identifier.doi10.4047/jap.2013.5.3.219-
dc.citation.journaltitleJournal of Advanced Prosthodontics-
dc.description.srndOAIID:oai:osos.snu.ac.kr:snu2013-01/102/2008003883/10-
dc.description.srndSEQ:10-
dc.description.srndPERF_CD:SNU2013-01-
dc.description.srndEVAL_ITEM_CD:102-
dc.description.srndUSER_ID:2008003883-
dc.description.srndADJUST_YN:N-
dc.description.srndEMP_ID:A078517-
dc.description.srndDEPT_CD:861-
dc.description.srndCITE_RATE:0-
dc.description.srndFILENAME:첨부된 내역이 없습니다.-
dc.description.srndDEPT_NM:치의학과-
dc.description.srndEMAIL:pros53@snu.ac.kr-
dc.description.srndSCOPUS_YN:N-
dc.description.srndCONFIRM:Y-
dc.identifier.srnd2013-01/102/2008003883/10-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share