Publications
Detailed Information
Silicon Retinal Tack for the Epiretinal Fixation of the Polyimide Electrode Array
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Seo, Jong-Mo | - |
dc.contributor.author | Paik, Seung Joon | - |
dc.contributor.author | Kim, Eui Tae | - |
dc.contributor.author | Byun, Sang Won | - |
dc.contributor.author | Lee, Ah Ra | - |
dc.contributor.author | Cho, Dongil | - |
dc.contributor.author | Kim, Sung June | - |
dc.contributor.author | Yu, Hyeong Gon | - |
dc.contributor.author | Yu, Young Suk | - |
dc.contributor.author | Chung, Hum | - |
dc.date.accessioned | 2009-09-07T06:54:05Z | - |
dc.date.available | 2009-09-07T06:54:05Z | - |
dc.date.issued | 2006-07 | - |
dc.identifier.citation | Curr. Appl. Phys. 6 (2006) 649 | en |
dc.identifier.issn | 1567-1739 | - |
dc.identifier.uri | https://hdl.handle.net/10371/8855 | - |
dc.description.abstract | Silicon-micromachined retinal tacks were developed for the fixation of the epiretinal-type retina-stimulating microelectrode
array. Silicon retinal tacks were fabricated by using the silicon on insulator (SOI) process, a method of releasing silicon structures in a SOI wafer. The dimensions of the retinal tack were substantially smaller than those of the conventional titanium tack, at 1.5 mm long, 150 lm wide, and 150 lm thick. To enhance the durability and biocompatibility of the retinal tack, 3 lm-thick parylene film was uniformly deposited on the entire surfaces. Short-term evaluation of the durability of the silicon retinal tack in vivo showed acceptable biocompatibility and firm fixation of the microelectrode array onto the retina. | en |
dc.description.sponsorship | This paper was supported by the Nano Bioelectronics
and Systems Research Center of Seoul National University, which is an ERC supported by the Korean Science and Engineering Foundation (KOSEF). | en |
dc.language.iso | en | - |
dc.publisher | Elsevier | en |
dc.subject | Biocompatibility | en |
dc.subject | Implant materials | en |
dc.subject | Parylene | en |
dc.subject | Silicon retinal tack | en |
dc.subject | Visual prosthesis | en |
dc.title | Silicon Retinal Tack for the Epiretinal Fixation of the Polyimide Electrode Array | en |
dc.type | Article | en |
dc.contributor.AlternativeAuthor | 서종모 | - |
dc.contributor.AlternativeAuthor | 박승준 | - |
dc.contributor.AlternativeAuthor | 김의태 | - |
dc.contributor.AlternativeAuthor | 변상원 | - |
dc.contributor.AlternativeAuthor | 이아라 | - |
dc.contributor.AlternativeAuthor | 조동일 | - |
dc.contributor.AlternativeAuthor | 김성준 | - |
dc.contributor.AlternativeAuthor | 유형곤 | - |
dc.contributor.AlternativeAuthor | 유영석 | - |
dc.contributor.AlternativeAuthor | 정흠 | - |
dc.identifier.doi | 10.1016/j.cap.2005.04.013 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.