Publications

Detailed Information

The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial

DC Field Value Language
dc.contributor.authorOh, Ah-Young-
dc.contributor.authorJeon, Young-Tae-
dc.contributor.authorChoi, Eun-Joo-
dc.contributor.authorRyu, Jung-Hee-
dc.contributor.authorHwang, Jung-Won-
dc.contributor.authorPark, Hee-Pyoung-
dc.contributor.authorDo, Sang-Hwan-
dc.date.accessioned2014-04-07T01:04:06Z-
dc.date.available2014-04-07T01:04:06Z-
dc.date.issued2014-02-28-
dc.identifier.citationBMC Anesthesiology Vol.14, pp.1-4ko_KR
dc.identifier.issn1471-2253-
dc.identifier.urihttps://hdl.handle.net/10371/91354-
dc.description.abstractBackground : It has been reported that the direction of the guidewire J-tip is associated with misplacement of a central venous catheter. We hypothesized that real-time ultrasound-guided infraclavicular subclavian venous cannulation would be less influenced by the direction of guidewire J-tip compared to landmark method.

Methods : Sixty adult patients who required subclavian venous catheterization for neurosurgery were enrolled in this prospective randomized controlled study. Patients were randomly divided into a landmark group (n = 30) or an ultrasound group (n = 30). After the subclavian vein was punctured, the guidewire was advanced with the guidewire J-tip directed cephalad. Misplacement or advancement failure of the guidewire was regarded as an unsuccessful placement. Postoperative chest radiography was performed to confirm pneumothorax and the location of the catheter tip.

Results : The two groups were comparable with respect to age, gender, height, and weight distribution. The incidence of unsuccessful guidewire placement was lower in the ultrasound group than in the landmark group (13% vs. 47%, P = 0.01). Among the unsuccessful guidewire placements, the incidence of misplacement were comparable between the groups and were all located in the ipsilateral internal jugular vein (7% vs. 7%). However, the incidence of advancement failure was significantly higher in landmark group (40% vs. 7%, P = 0.005). There were no complications such as pneumothorax or hemothorax.

Conclusions : The proper placement of guidewire was less influenced by the direction of the guidewire J-tip with ultrasound-guided subclavian venous cannulation than with the landmark approach.
ko_KR
dc.language.isoenko_KR
dc.publisherBioMed Central Ltd-
dc.subjectCentral venous catheterizationko_KR
dc.subjectSubclavian veinko_KR
dc.subjectUltrasoundko_KR
dc.titleThe influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trialko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor오아영-
dc.contributor.AlternativeAuthor전영태-
dc.contributor.AlternativeAuthor류정희-
dc.contributor.AlternativeAuthor황정원-
dc.contributor.AlternativeAuthor박희평-
dc.contributor.AlternativeAuthor도상환-
dc.identifier.doi10.1186/1471-2253-14-11-
dc.citation.journaltitleBMC Anesthesiology-
dc.language.rfc3066en-
dc.description.versionPeer Reviewed-
dc.rights.holderAh-Young Oh et al.; licensee BioMed Central Ltd.-
dc.date.updated2014-04-04T06:27:09Z-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share