Publications

Detailed Information

Monitoring the Quality of Robot-Assisted Pedicle Screw Fixation in the Lumbar Spine by Using a Cumulative Summation Test

DC Field Value Language
dc.contributor.authorKim, Ho-Joong-
dc.contributor.authorLee, Seung Hoo-
dc.contributor.authorChang, Bong-Soon-
dc.contributor.authorLee, Choon-Ki-
dc.contributor.authorLim, Teck Onn-
dc.contributor.authorHoo, Ling Ping-
dc.contributor.authorYi, Je-Min-
dc.contributor.authorYeom, Jin S.-
dc.creator염진섭-
dc.date.accessioned2015-05-26T07:20:58Z-
dc.date.available2015-05-26T07:20:58Z-
dc.date.issued2015-01-
dc.identifier.citationSpine, Vol.40 No.2, pp. 87-94-
dc.identifier.issn0362-2436-
dc.identifier.urihttps://hdl.handle.net/10371/94230-
dc.description.abstractStudy Design. Prospective randomized controlled trial.Objective. The aim of this study was to monitor the quality control of robot-assisted pedicle screw fixation accuracy by using a cumulative summation (CUSUM) test at the initial stage of its application.Summary of Background Data. Although robot-assisted pedicle screw fixation reduces screw misplacement rates and provides critical support for minimally invasive surgical procedures, there have been no reports relating to the monitoring of quality control of the accuracy of this robot-assisted pedicle screw fixation procedure.Methods. Patients with lumbar spinal stenosis scheduled to undergo surgery were randomly and equally assigned through 1:1 allocation to a robot-assisted minimally invasive posterior lumbar interbody fusion (Rom-PLIF) group or a conventional open posterior PLIF using freehand technique group. The accuracy of pedicle screw placement was evaluated using postoperative computed tomography. The primary outcome was the CUSUM analysis for monitoring the quality control of the accuracy of pedicle screw insertion between the Rom-PLIF and conventional open posterior PLIF using freehand technique groups.Results. Of the 80 pedicle screws inserted in each group, 4 screws in the Rom-PLIF group, and 7 in the conventional open PLIF group, breached the pedicle. Of these 11 offending screws, 4 cases were categorized as grade B in the Rom-PLIF group, whereas 6 were grade B and 1 case was grade C in the Com-PLIF group, using the Gertzbein and Robbins classification. Throughout the monitoring period, there was no CUSUM test-derived indication that the quality of performance of the pedicle screw fixation procedure was inadequate in either group.Conclusion. First, this study demonstrates the adequacy of quality control of robot-assisted pedicle screw fixation even early in the application period based on the CUSUM analysis. Second, the CUSUM test can be a useful tool for monitoring of the quality of procedures related with spine surgery.en
dc.language.isoenen
dc.publisherLippincott, Williams & Wilkinsen
dc.subject의약학en
dc.subjectrobot-assisted pedicle screw fixation-
dc.subjectcumulative summation-
dc.subjectfreehand technique-
dc.subjectposterior lumbar interbody fusion-
dc.titleMonitoring the Quality of Robot-Assisted Pedicle Screw Fixation in the Lumbar Spine by Using a Cumulative Summation Testen
dc.typeArticle-
dc.contributor.AlternativeAuthor김호중-
dc.contributor.AlternativeAuthor이승후-
dc.contributor.AlternativeAuthor장봉순-
dc.contributor.AlternativeAuthor이춘기-
dc.contributor.AlternativeAuthor임택언-
dc.contributor.AlternativeAuthor이제민-
dc.contributor.AlternativeAuthor염진섭-
dc.identifier.doi10.1097/BRS.0000000000000680-
dc.description.srndOAIID:oai:osos.snu.ac.kr:snu2015-01/102/0000004226/2-
dc.description.srndSEQ:2-
dc.description.srndPERF_CD:SNU2015-01-
dc.description.srndEVAL_ITEM_CD:102-
dc.description.srndUSER_ID:0000004226-
dc.description.srndADJUST_YN:Y-
dc.description.srndEMP_ID:A079510-
dc.description.srndDEPT_CD:801-
dc.description.srndCITE_RATE:2.447-
dc.description.srndFILENAME:spine-2015_kim_monitoring the quality of robot assisted pedicle screw fixation in the lumbar spine.pdf-
dc.description.srndDEPT_NM:의학과-
dc.description.srndSCOPUS_YN:Y-
dc.description.srndCONFIRM:Y-
dc.identifier.srnd2015-01/102/0000004226/2-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share